Rev: - | Copyright © 2022 - 2026 Marki Microwave LLC.

General Description

M1 double balanced mixers are hybrid assemblies that have been hand-tuned to feature low conversion loss and high isolations and a DC IF response. M1 mixers have generally been replaced with MM1 mixers with superior performance, repeatability, and availability. M1 mixers are still used in legacy systems and are suitable for laboratory use.

Features

  • LO/RF 6.0 to 20.0 GHz
  • IF DC to 6.0 GHz
  • 5.5 dB Typical Conversion Loss
  • 40 dB Typical LO to RF Isolation
  • Broadband RF and LO

Functional Block Diagram

Block Diagram
Photo of M1-0620NE-1

Electrical Performance Summary

ParameterTypUnit
Conversion Loss 6.5dB
RF Frequency Range 6 to 20GHz
Input IP3 18dBm
LO Input Power 13 to 16-
IF Frequency Range 0 to 6GHz

Summary only – refer to the Electrical Specifications, Absolute Maximum Ratings, and Recommended Operating Range tables for complete details.

Part Ordering Options

Part NumberDescriptionPackageGreen StatusProduct LifecycleExport ClassificationRecommended Replacement
M1-0620SE-2Double-Balanced MixersE

Non-RoHS

Not Recommended for New DesignEAR99MM1-0626HSM-2MM1-0626SSM-2
M1-0620HE-2Double-Balanced MixersE

Non-RoHS

End of LifeEAR99MM1-0626HSM-2
M1-0620NE-1Double-Balanced MixersEConsult FactoryNot Recommended for New DesignEAR99MM1-0626HSM-2
M1-0620ME-2Double-Balanced MixersE

Non-RoHS

Not Recommended for New DesignEAR99MM1-0222LSM-2MM1-0626HSM-2
M1-0620ME-1Double-Balanced MixersEConsult FactoryNot Recommended for New DesignEAR99MM1-0222LSM-2MM1-0626HSM-2
M1-0620LE-2Double-Balanced MixersE

Non-RoHS

End of LifeEAR99MM1-0222LSM-2MM1-0626HSM-2
M1-0620LE-1Double-Balanced MixersEConsult FactoryEnd of LifeEAR99MM1-0222LSM-2MM1-0626HSM-2
M1-0620NE-2Double-Balanced MixersEConsult FactoryNot Recommended for New DesignEAR99MM1-0626HSM-2

Table Of Contents

Specifications

Electrical Specifications

Specifications guaranteed from -55 to +100°C, measured in a 50-Ohm system.

ParameterTest ConditionsMinimum
Frequency
(GHz)
Maximum
Frequency
(GHz)
MinTypMaxUnit
Conversion Loss LO/RF=6-20 GHz
IF=3-6 GHz
6 20-6.58.5dB
Conversion Loss LO/RF=6-20 GHz
IF=DC-3 GHz
6 20-5.57.5dB
Input IP3 1LO/RF=6-20 GHz
LO drive level, N Diode Option=13-16 dBm
6 20-18-dBm
Input P1dB 2LO/RF=6-20 GHz
LO drive level, N Diode Option=13-16 dBm
6 20-8-dBm
LO-IF Isolation LO/RF=6-20 GHz
6 20-20-dB
LO-RF Isolation LO/RF=6-20 GHz
6 203040-dB
RF-IF Isolation LO/RF=6-20 GHz
6 20-25-dB
IF Frequency Range -- -0-6GHz
Input IP3 -- --18-dBm
Input P1dB -- --8-dBm
RF Frequency Range -- -6-20GHz

[1][2] 1-dB Compression and Third Order Intercept are degraded for LO frequencies below 13 GHz

ParameterMinNominalMaxUnit
LO Input Power 13-16-

Package Information

ParameterDetailsRating
WeightPackage name: E1g
Dimensions-15.24 x 8.13 mm

Port Configuration and Functions

Port Functions

PortFunctionDescriptionDC Equivalent
Circuit
RFRF The RF port is DC coupled to ground and AC matched to 50 Ohms from 6 to 20 GHz. Blocking capacitor is optional.Equivalent circuit for the RF
LOLO The LO port is DC coupled to ground and AC matched to 50 Ohms from 6 to 20 GHz. Blocking capacitor is optional.Equivalent circuit for the LO
IFIF The IF port is DC coupled to the diodes and AC matched to 50 Ohms from 0 to 6 GHz. Blocking capacitor is optional.Equivalent circuit for the IF

Mechanical Data

Outline Drawing

Outline Drawing

Notes

DATA SHEET NOTES:

1. Mixer Conversion Loss Plot IF frequency is 100 MHz.
2. Mixer Noise Figure typically measures within +0.5 dB of conversion loss for IF frequencies greater than 5 MHz.
3. Conversion Loss typically degrades less than 0.5 dB for LO drives 2 dB below the lowest and 3 dB above highest nominal LO drive levels.
4. Conversion Loss typically degrades less than 0.5 dB at +100°C and improves less than 0.5 dB at -55°C.
5. Maximum input power is +23 dBm at +25°C, derated linearly to +20 dBm at +100°C.
6. Specifications are subject to change without notice. Contact Marki Microwave for the most recent specifications and data sheets.
7. Standard configuration for A, B, and C outlines are with connectors and bottom spacer.
8. Catalog mixer circuits are continually improved. Configuration control requires custom mixer model numbers and specifications.

DISCLAIMER

MARKI MICROWAVE, LLC., (“MARKI”) PROVIDES TECHNICAL SPECIFICATIONS AND DATA (INCLUDING DATASHEETS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, AND OTHER INFORMATION AND RESOURCES “AS IS” AND WITH ALL FAULTS. MARKI DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT.

These resources are intended for developers skilled in the art designing with Marki products. You are solely responsible for (1) selecting the appropriate products for your application, (2) designing, validating, and testing your application, and (3) ensuring your application meets applicable standards and other requirements. Marki makes no guarantee regarding the suitability of its products for any particular purpose, nor does Marki assume any liability whatsoever arising out of your use or application of any Marki product.

Marki grants you permission to use these resources only for development of an application that uses Marki products. Other reproduction or use of these resources is strictly prohibited. No license is granted to any other Marki intellectual property or to any third-party intellectual property. Marki reserves the right to make changes to the product(s) or information contained herein without notice.

MARKI MICROWAVE, M wave logo, FastSwitch, and T3 MIXER are trademarks or registered trademarks of Marki Microwave, LLC. All other trademarks used are the property of their respective owners.

© 2022 - 2026, Marki Microwave, LLC