Rev: A | Copyright © 2015, 2019 Marki Microwave LLC.

General Description

The MM1-0320HSM is a passive GaAs double balanced MMIC mixer suitable for both up and down-conversion applications. As with all Marki Microwave mixers, it features excellent conversion loss, isolation and spurious performance across a broad bandwidth and in a small form factor. The MM1-0320HSM is available in a lead-free, RoHS compliant QFN surface mount package and is compatible with standard leaded and lead-free PCB reflow soldering processes. The MM1-0320HSM is a superior alternative to Marki Microwave surface mount M1 and M3 mixers.

Features

  • Compact 3mm QFN SMT Style Package
  • Broadband Performance
  • Excellent Unit-to-Unit Repeatability
  • RoHS Compliant

Functional Block Diagram

Block Diagram
Photo of MM1-0320HSM-2

Electrical Performance Summary

ParameterTypUnit
Conversion Loss 8dB
RF Frequency Range 3.5 to 20GHz
Input IP3 20dBm
IF Frequency Range 0 to 4GHz

Summary only – refer to the Electrical Specifications, Absolute Maximum Ratings, and Recommended Operating Range tables for complete details.

Part Ordering Options

Part NumberDescriptionPackagePacking SizeGreen StatusProduct LifecycleExport Classification
MM1-0320HSM-2GaAs Double-Balanced MixerQFN-

REACH

RoHS

ReleasedEAR99
EVAL-MM1-0320HEvaluation Board, GaAs DOUBLE-BALANCED MIXEREVAL-

REACH

RoHS

ReleasedEAR99
MM1-0320H-2-TRTape and Reel, GaAs Double-Balanced MixerQFN7"

REACH

RoHS

ReleasedEAR99

Table Of Contents

Typical Performance

Conversion Loss (dB) graph for MM1-0320HSM-2
Relative IF Response (dB) graph for MM1-0320HSM-2
Configuration A Conversion Loss vs. LO Power (dB) graph for MM1-0320HSM-2
Configuration B Conversion Loss vs. LO Power (dB) graph for MM1-0320HSM-2
Input IP3 (dBm) graph for MM1-0320HSM-2
Output IP3 (dBm) graph for MM1-0320HSM-2
LO to RF Isolation (dB) graph for MM1-0320HSM-2
LO to IF Isolation (dB) graph for MM1-0320HSM-2
RF to IF Isolation (dB) graph for MM1-0320HSM-2
IF Return Loss (dB) graph for MM1-0320HSM-2
RF Return Loss (dB) graph for MM1-0320HSM-2
LO Return Loss (dB) graph for MM1-0320HSM-2
Even LO Harmonic to RF Isolation (dB) graph for MM1-0320HSM-2
Even LO Harmonic to IF Isolation (dB) graph for MM1-0320HSM-2
Odd LO Harmonic to RF Isolation (dB) graph for MM1-0320HSM-2
Even LO Harmonic to IF Isolation (dB) graph for MM1-0320HSM-2
2RF x 2LO Spurious Suppression (dBc) -10 dBm RF Input graph for MM1-0320HSM-2
2IF x 1LO Spurious Suppression (dBc) -10 dBm IF input graph for MM1-0320HSM-2

Specifications

Electrical Specifications

Specifications guaranteed from -55 to +100°C, measured in a 50Ω system.

ParameterPort ConfigurationTest ConditionsMinimum
Frequency
(GHz)
Maximum
Frequency
(GHz)
MinTypMaxUnit
Conversion Loss ALO/RF=3.5-20 GHz
IF=DC-4 GHz
3.5 20-813dB
IF Frequency Range A-- -0-4GHz
Input IP3 ALO/RF=3.5-20 GHz
IF=DC-4 GHz
LO Drive Level=13-20dBm
3.5 20-20-dBm
Input P1dB ALO/RF=3.5-20 GHz
IF=DC-4 GHz
LO Drive Level=13-20dBm
3.5 20-9-dBm
LO Frequency Range A-- -3.5-20GHz
RF Frequency Range A-- -3.5-20GHz
Conversion Loss BLO/RF=3.5-20 GHz
IF=DC-4 GHz
3.5 20-916dB
Input IP3 BLO/RF=3.5-20 GHz
IF=DC-4 GHz
LO Drive Level=12-17dBm
3.5 20-20-dBm
Input P1dB BLO/RF=3.5-20 GHz
IF=DC-4 GHz
LO Drive Level=12-17dBm
3.5 20-9-dBm
LO-RF Isolation --- --49-dB

Absolute Maximum Ratings

ParameterMaximum RatingUnit
Maximum Operating Temperature 100°C
Maximum Storage Temperature 125°C
Minimum Operating Temperature -55°C
Minimum Storage Temperature -65°C
Port 2 DC Current 15mA
Port 5 DC Current 30mA
Port 8 DC Current 15mA
RF Power Handling (RF+LO), 100°C 21dBm
RF Power Handling (RF+LO), 25°C 25dBm

Package Information

ParameterDetailsRating
Dimensions-3 x 3 mm
Moisture Sensitivity Level-MSL 1

Port Configuration and Functions

Port Diagram

Diagram of the port configuration for MM1-0320HSM-2

Port Functions

Configuration A

PortFunctionDescriptionDC Equivalent
Circuit
Port 5IF Port 5 is DC coupled to the diodes. Blocking capacitor is optional.Equivalent circuit for the IF
Port 2LO Port 2 is DC short to ground and AC matched to 50 Ohms from 3.5 to 20 GHz. Blocking capacitor is optional.Equivalent circuit for the LO
Port 8RF Port 8 is DC short to ground and AC matched to 50 Ohms from 3.5 to 20 GHz. Blocking capacitor is optional.Equivalent circuit for the RF

Configuration B

PortFunctionDescriptionDC Equivalent
Circuit
Port 8LO Port 8 is DC short to ground and AC matched to 50 Ohms from 3.5 to 20 GHz. Blocking capacitor is optional.Equivalent circuit for the LO
Port 5IF Port 5 is DC coupled to the diodes. Blocking capacitor is optional.Equivalent circuit for the IF
Port 2RF Port 2 is DC short to ground and AC matched to 50 Ohms from 3.5 to 20 GHz. Blocking capacitor is optional.Equivalent circuit for the RF

Spur Table

Downconversion Spurious Suppression


Spurious data is taken by selecting RF and LO frequencies (+mLO+nRF) within the RF/LO bands, to create a spurious output within the IF output band. The mixer is swept across the full spurious band and the mean is calculated. The numbers shown in the table below are for a -10 dBm RF input. Spurious suppression is scaled for different RF power levels by (n-1), where “n” is the RF spur order. For example, the 2RFx2LO spur is 68 dBc for the A configuration for a -10 dBm input, so a -20 dBm RF input creates a spur that is (2-1) x (-10 dB) dB lower, or 78 dBc.

M M1 0320 Hsm 2 Typical Down Conversion

M M1 0320 Hsm 2 Typical Down Conversion

Upconversion Spurious Suppression


Spurious data is taken by mixing an input within the IF band, with LO frequencies (+mLO+nIF), to create a spurious output within the RF output band. The mixer is swept across the full spurious output band and the mean is calculated. The numbers shown in the table below are for a -10 dBm IF input. Spurious suppression is scaled for different IF input power levels by (n-1), where “n” is the IF spur order. For example, the 2IFx1LO spur is typically 70 dBc for the A configuration for a -10 dBm input, so a -20 dBm IF input creates a spur that is (2-1) x (-10 dB) dB lower, or 80 dBc.

M M1 0320 Hsm 2 Typical up Conversion

Operation

Application Circuit

Application Circuit for MM1-0320HSM-2

Application Circuit Description

Operation

IF Port – Used as input on an upconversion, output on downconversion, or LO port in a band shifting application. Signals should be connected by 50 ohm microstrip or coplanar traces to well matched broadband 50 ohm sources and loads. Blocking capacitor is recommended if DC voltage is present on the line.

RF Port – Used as input on a downconversion, output on upconversion, or output in a band shifting application. Signals should be connected by 50 ohm microstrip or coplanar traces to well matched broadband 50 ohm sources and loads.

Filtering and Matching- Filtering is generally desired for spurious and image removal on the output port of the mixer. Reflective filters can cause out of band signals to reflect back into the mixer and cause conversion loss ripple, erroneous spurs, and other undesired behaviors. To eliminate these problems it is recommend that the filters be placed as close to the output port as possible. If undesired behavior is still observed, a diplexer with one port terminated or a 1-3 dB attenuator may reduce this problem.

RF Ground – The ground paddle of the QFN should be connected to a low noise RF ground with very low electrical resistance for high frequency operation.

LO Port – The noise floor of the LO input signal should be less than the value of the noise floor plus isolation of the mixer, or a filter is recommended to prevent reduction in dynamic range. An LO amplifier is required if the LO power is below the recommended drive level. It is important to use an amplifier with a broadband 50 ohm match such that it does not reflect spurious signals back into the mixer or other system circuitry.

Mechanical Data

Outline Drawing

Download : Outline 2D Drawing Outline 3D Drawing Outline 3D STP

Outline Drawing

Revision History

Revision CodeRevision DateComment
-2015-10-01Initial Release
A2019-04-01Updated plating to ENEPIG

Notes

  1. Mixer Conversion Loss Plot IF frequency is 100 MHz.
  2. Mixer Noise Figure typically measures within 0.5 dB of conversion loss for IF frequencies greater than 5 MHz.
  3. Conversion Loss typically degrades less than 0.5 dB at +100°C and improves less than 0.5 dB at -55°C.
  4. Unless otherwise specified, data is taken with +15 dBm LO drive.
  5. Specifications are subject to change without notice. Contact Marki Microwave for the most recent specifications and data sheets.
  6. Catalog mixer circuits are continually improved. Configuration control requires custom mixer model numbers and specifications.

DISCLAIMER

MARKI MICROWAVE, LLC., (“MARKI”) PROVIDES TECHNICAL SPECIFICATIONS AND DATA (INCLUDING DATASHEETS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, AND OTHER INFORMATION AND RESOURCES “AS IS” AND WITH ALL FAULTS. MARKI DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT.

These resources are intended for developers skilled in the art designing with Marki products. You are solely responsible for (1) selecting the appropriate products for your application, (2) designing, validating, and testing your application, and (3) ensuring your application meets applicable standards and other requirements. Marki makes no guarantee regarding the suitability of its products for any particular purpose, nor does Marki assume any liability whatsoever arising out of your use or application of any Marki product.

Marki grants you permission to use these resources only for development of an application that uses Marki products. Other reproduction or use of these resources is strictly prohibited. No license is granted to any other Marki intellectual property or to any third-party intellectual property. Marki reserves the right to make changes to the product(s) or information contained herein without notice.

MARKI MICROWAVE, M wave logo, FastSwitch, and T3 MIXER are trademarks or registered trademarks of Marki Microwave, LLC. All other trademarks used are the property of their respective owners.

© 2015, 2019, Marki Microwave, LLC