NOT RECOMMENDED FOR NEW DESIGN

Device Overview

General Description

M1 double balanced mixers are hybrid assemblies that have been hand-tuned to feature low conversion loss and high isolations and a DC IF response. M1 mixers have generally been replaced with MM1 mixers with superior performance, repeatability, and availability. M1 mixers are still used in legacy systems and are suitable for laboratory use.

Photo of M1-0620SP

Features

  • LO/RF 6.0 to 20.0 GHz
  • IF DC to 6.0 GHz
  • 5.5 dB Typical Conversion Loss
  • 40 dB Typical LO to RF Isolation
  • Broadband RF and LO

Applications

N/A

Functional Block Diagram

Block Diagram

Part Ordering Options

Part NumberDescriptionPackageConnectorsGreen StatusProduct LifecycleExport ClassificationRecommended Replacement
M1-0620SPDouble-Balanced MixersPStandardConsult FactoryNot Recommended for New DesignEAR99MM1-0626HSMM1-0626SS
M1-0620MPDouble-Balanced MixersPStandard

Non-RoHS

Not Recommended for New DesignEAR99MM1-0222LSMM1-0626HS
M1-0620NPDouble-Balanced MixersPStandardConsult FactoryEnd of LifeEAR99MM1-0626HS
M1-0620HPDouble-Balanced MixersPStandardConsult FactoryEnd of LifeEAR99MM1-0626HS
M1-0620LPDouble-Balanced MixersPStandardConsult FactoryEnd of LifeEAR99MM1-0222LSMM1-0626HS

Table Of Contents

Rev: - | Copyright © 2022 - 2026 Marki Microwave LLC.

2

Port Configuration and Functions

Port Functions

PortFunctionConnector TypeDescriptionDC Equivalent
Circuit
Port 1LO SMAFPort 1 is DC short for the P package.Equivalent circuit for the LO
Port 2IF SMAFPort 2 is diode connected for the P Package.Equivalent circuit for the IF
Port 3RF SMAFPort 3 is DC short for the P Package.Equivalent circuit for the RF

Rev: - | Copyright © 2022 - 2026 Marki Microwave LLC.

3

Specifications

Package Information

ParameterDetailsRating
WeightPackage name: P18g
Dimensions-20.32 x 14.99 mm
ParameterMinNominalMaxUnit
LO Input Power 19-22-

Rev: - | Copyright © 2022 - 2026 Marki Microwave LLC.

4

Electrical Specifications

Specifications guaranteed from -55 to +100°C, measured in a 50-Ohm system.

ParameterTest ConditionsMinTypMaxUnit
Conversion Loss LO/RF=6-20 GHz
IF=3-6 GHz
-6.58.5dB
Conversion Loss LO/RF=6-20 GHz
IF=DC-3 GHz
-5.57.5dB
Input IP3 1LO/RF=6-20 GHz
LO drive level, S Diode Option=19-22 GHz
-24-dBm
Input P1dB 2LO/RF=6-20 GHz
LO drive level, S Diode Option=19-22 GHz
-14-dBm
LO-IF Isolation LO/RF=6-20 GHz
-20-dB
LO-RF Isolation LO/RF=6-20 GHz
3040-dB
RF-IF Isolation LO/RF=6-20 GHz
-25-dB
IF Frequency Range -0-6GHz
RF Frequency Range -6-20GHz

[1][2] 1-dB Compression and Third Order Intercept are degraded for LO frequencies below 13 GHz

Rev: - | Copyright © 2022 - 2026 Marki Microwave LLC.

5

Mechanical Data

Outline Drawing

Download : Outline 3D Drawing Outline 3D STP

Outline Drawing

Rev: - | Copyright © 2022 - 2026 Marki Microwave LLC.

6