Rev: B | Copyright © 2020, 2023, 2026 Marki Microwave LLC.

General Description

The T3H-18G is a high performance mixer featuring LO/RF from 10 MHz to 18 GHz and IF from 10 MHz to 18 GHz. As with all T3 mixers, this mixer offers unparalleled nonlinear performance in terms of IIP3, P1dB, and spurious performance with a flexible LO drive requirement from +15 dBm to +25 dBm. The T3H-18G is offered in connectorized, surface mount, and drop-in style packaging, suitable for any type of system level integration. The T3H-18G is a form-fit-function replacement for the obsolete T3H-18, built using GaAs diodes instead of Si.

Features

  • Ultra-Broadband RF, LO, and IF
  • Compatible with Sine or Square-Wave LO
  • Square-Wave LO delivers Industry-Leading Spurious, IP3, and P1dB Performance

Functional Block Diagram

Block Diagram
Photo of T3H-18GLCTG-2

Electrical Performance Summary

ParameterTypUnit
Conversion Loss 9.5dB
RF Frequency Range 0.01 to 18GHz
Input IP3 32dBm
LO Input Power 15 to 25-
IF Frequency Range 0.01 to 18GHz

Summary only – refer to the Electrical Specifications, Absolute Maximum Ratings, and Recommended Operating Range tables for complete details.

Part Ordering Options

Part NumberDescriptionPackageGreen StatusProduct LifecycleExport Classification
T3H-18GICTG-1Two-Tone-Terminator .01 - 18 GHz MixerCTG

REACH

RoHS

ReleasedEAR99
T3H-18GICTG-2Two-Tone Terminator MixerCTG

REACH

RoHS

ReleasedEAR99
T3H-18GLCTG-2Two-Tone-Terminator .01 - 18 GHz MixerCTG

REACH

RoHS

ReleasedEAR99
T3H-18GLCTG-1Two-Tone-Terminator .01 - 18 GHz MixerCTG

REACH

RoHS

ReleasedEAR99

Table Of Contents

Typical Performance Plots

Conversion Loss (dB) graph for T3H-18GLCTG-2
Input IP3 (dBm) graph for T3H-18GLCTG-2
Input 1-dB Compression (dBm) vs. LO Power @ 4 GHz graph for T3H-18GLCTG-2
Input IP3 (dBm) vs. LO Power @ 4 GHz graph for T3H-18GLCTG-2
Relative IF Response (dB) graph for T3H-18GLCTG-2
Relative IF Response (dB) graph for T3H-18GLCTG-2
RF VSWR graph for T3H-18GLCTG-2
LO VSWR graph for T3H-18GLCTG-2
RF to IF Isolation (dB) graph for T3H-18GLCTG-2
IF VSWR graph for T3H-18GLCTG-2
LO to RF Isolation (dB) graph for T3H-18GLCTG-2
LO to IF Isolation (dB) graph for T3H-18GLCTG-2
LO Even Harmonic to RF Isolation (dB) graph for T3H-18GLCTG-2
LO Odd Harmonic to RF Isolation (dB) graph for T3H-18GLCTG-2
LO Even Harmonic to IF Isolation (dB) graph for T3H-18GLCTG-2
LO Odd Harmonic to IF Isolation (dB) graph for T3H-18GLCTG-2

Specifications

Electrical Specifications

Specifications guaranteed from -55 to +100°C, measured in a 50Ω system.

ParameterTest ConditionsMinimum
Frequency
(GHz)
Maximum
Frequency
(GHz)
MinTypMaxUnit
Conversion Loss LO/RF=0.01-18GHz, IF=91 MHz
0.01 18-9.515.5dB
Conversion Loss RF=14GHz, LO=13.99-0.01 GHz, IF= 0.01-13.99 GHz
0.01 18-9.515.5dB
LO-IF Isolation LO/RF= 0.01-18 GHz
0.01 1815--dB
LO-RF Isolation LO/RF= 0.01-18 GHz
0.01 1815--dB
IF Frequency Range -- -0.01-18GHz
Input IP3 -- --32-dBm
RF Frequency Range -- -0.01-18GHz
ParameterMinNominalMaxUnit
LO Input Power 15-25-

Absolute Maximum Ratings

ParameterMaximum RatingUnit
LO DC Current 1Amp
Maximum Operating Temperature 100°C
Maximum Storage Temperature 125°C
Minimum Operating Temperature -55°C
Minimum Storage Temperature -65°C
RF DC Current 1Amp
RF Power Handling (RF+LO), (L -Version) 25°C

Package Information

ParameterDetailsRating
ESD250 to < 500 VoltsHBM Class 1A
Dimensions-8.13 x 8.13mm
Moisture Sensitivity Level-MSL 1

Port Configuration and Functions

Port Functions

PortFunctionDescriptionDC Equivalent
Circuit
RFRF The RF port is DC short to ground and AC matched to 50 Ohms from 10 MHz to 18 GHz. Blocking capacitor is optional.Equivalent circuit for the RF
LOLO The LO port is DC short to ground and AC matched to 50 Ohms from 10 MHz to 18 GHz. Blocking capacitor is optional.Equivalent circuit for the LO
IFIF The IF port is DC blocked and AC matched to 50 Ohms from 10 MHz to 18 GHz.Equivalent circuit for the IF

Spur Table

Downconversion Spurious Suppression

Spurious data is taken by selecting RF and LO frequencies (+mLO+nRF) within the 10 MHz to 18 GHz RF/LO bands, which create a 100 MHz IF spurious output. The mixer is swept across the full spurious band and the mean is calculated. The numbers shown in the table below are for a -10 dBm RF input. Spurious suppression is scaled for different RF power levels by (n-1), where “n” is the RF spur order. For example, the 2RFx2LO spur is 61 dBc for a -10 dBm input, so a -20 dBm RF input creates a spur that is (2-1) x (-10 dB) dB lower, or 71 dBc.

Typical Downconversion Spurious Suppression (dBc): Square Wave (Sine Wave) LO5

-10 dBm RF Input

0xLO

1xLO

2xLO

3xLO

4xLO

5xLO

0xRF

-------------

See LO to IF Isolation and LO Harmonic to IF Isolation Plots (Page 3)

1xRF

17 (18)

Reference

19 (27)

10 (11)

19 (34)

16 (18)

2xRF

60 (59)

65 (60)

61 (57)

65 (62)

63 (53)

64 (55)

3xRF

101 (96)

85 (75)

92 (86)

88 (81)

97 (92)

90 (76)

4xRF

>110

>110

>110

>110

>110

>110

5xRF

>120

>120

>120

>120

>120

>120

A sample downconversion spurious sweep is shown below. An LO which is 100 MHz higher than the RF is used to create a 100 MHz reference IF. A second LO is used to create a 2x2 spurious IF, also at 100 MHz (50 MHz fundamental IF). The difference between these two output levels is the spurious suppression in dBc. The mean value across the full 10 MHz to 18 GHz RF input band is the number shown in the table above.

T3 H 18 G Downconversion Spurious

Upconversion Spurious Suppression

Spurious data is taken by mixing a 100 MHz IF with LO frequencies (+mLO+nIF), which creates an RF within the 10 MHz to 18 GHz RF band. The mixer is swept across the full spurious output band and the mean is calculated. The numbers shown in the table below are for a -10 dBm IF input. Spurious suppression is scaled for different IF input power levels by (n-1), where “n” is the IF spur order. For example, the 2IFx1LO spur is typically 60 dBc for a -10 dBm input, so a -20 dBm IF input creates a spur that is (2-1) x (-10 dB) dB lower, or 70 dBc.

Typical Upconversion Spurious Suppression (dBc): Square Wave (Sine Wave) LO5

-10 dBm IF Input

0xLO

1xLO

2xLO

3xLO

4xLO

5xLO

0xIF

-------------

See LO to RF Isolation and LO Harmonic to RF Isolation Plots (Page 3)

1xIF

18 (17)

Reference

18 (22)

11 (11)

18 (27)

16 (18)

2xIF

62 (62)

60 (54)

60 (49)

67 (55)

61 (48)

64 (52)

3xIF

73 (72)

86 (72)

95 (78)

90 (66)

95 (69)

91 (65)

4xIF

>110

>110

>110

>110

>110

>110

5xIF

>120

>120

>120

>120

>120

>120

A sample upconversion spurious sweep is shown below. A 100 MHz reference IF input is used to create an RF output that is 100 MHz below the LO input (LO-IF=RF). A second LO (100 MHz higher) is combined with the same 100 MHz IF input (LO-2xIF=RF) to create the same 10 MHz to 18 GHz RF output band. The difference between these two output levels is the spurious suppression in dBc. The mean value across the full RF output band is the number shown in the table above.

T3 H 18 G Upconversion Spurious

Mechanical Data

Outline Drawing

Download : Outline 2D Drawing Outline 3D Drawing Outline 3D STP

Outline Drawing

Revision History

Revision CodeRevision DateComment
-2020-08-25Initial Release
A2023-12-19Revised conversion loss test conditions in electical specifications table.
B2026-03-17IF Frequency Range Corrected

Notes

DATA SHEET NOTES:
1. Mixer Conversion Loss Plot IF frequency is 100 MHz.
2. Mixer Noise Figure typically measures within 0.5 dB of conversion loss for IF frequencies greater than 5 MHz.
3. Conversion Loss typically degrades less than 0.5 dB for LO drives 2 dB below the lowest and 3 dB above highest nominal LO drive levels.
4. Conversion Loss typically degrades less than 0.5 dB at +100°C and improves less than 0.5 dB at -55°C.
5. Square Wave Drive created with a chain to two ADM1-0026PA, biased at + 7/-0.25 Volts, with a +10 dBm input. Sine Wave data is taken with a +20 dBm LO input.
6. Square Wave Drive created with an ADM1-0026PA, biased at + 7/-0.25 Volts, driving an ADM3-0022PA, biased at +7/+15/-0.25/-0.65V.
7. Specifications are subject to change without notice. Contact Marki Microwave for the most recent specifications and data sheets.
8. Catalog mixer circuits are continually improved. Configuration control requires custom mixer model numbers and specifications.

DISCLAIMER

MARKI MICROWAVE, LLC., (“MARKI”) PROVIDES TECHNICAL SPECIFICATIONS AND DATA (INCLUDING DATASHEETS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, AND OTHER INFORMATION AND RESOURCES “AS IS” AND WITH ALL FAULTS. MARKI DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT.

These resources are intended for developers skilled in the art designing with Marki products. You are solely responsible for (1) selecting the appropriate products for your application, (2) designing, validating, and testing your application, and (3) ensuring your application meets applicable standards and other requirements. Marki makes no guarantee regarding the suitability of its products for any particular purpose, nor does Marki assume any liability whatsoever arising out of your use or application of any Marki product.

Marki grants you permission to use these resources only for development of an application that uses Marki products. Other reproduction or use of these resources is strictly prohibited. No license is granted to any other Marki intellectual property or to any third-party intellectual property. Marki reserves the right to make changes to the product(s) or information contained herein without notice.

MARKI MICROWAVE, M wave logo, FastSwitch, and T3 MIXER are trademarks or registered trademarks of Marki Microwave, LLC. All other trademarks used are the property of their respective owners.

© 2020, 2023, 2026, Marki Microwave, LLC