NOT RECOMMENDED FOR NEW DESIGN

Device Overview

General Description

M2 triple balanced mixers are hybrid assemblies that have been hand-tuned to feature low conversion loss and high isolations. M2 mixers offer ultrabroadband overlapping frequency coverage on all 3 ports. Many M2 mixers have replaced with MM2 mixers with superior performance, repeatability, and availability. M2 mixers suitable for systems where an MM2 mixer is not available.

Photo of M2H-0226ME-2

Features

  • LO/RF 2.0 to 26.5 GHz
  • IF 1.0 to 10.0 GHz
  • 7.5 dB Typical Conversion Loss
  • 30 dB Typical LO to RF Isolation
  • Ultra-Broadband RF, LO, and IF

Applications

N/A

Functional Block Diagram

Block Diagram

Part Ordering Options

Part NumberDescriptionPackageGreen StatusProduct LifecycleExport ClassificationRecommended Replacement
M2H-0226LE-2Triple-Balanced MixersEConsult FactoryEnd of LifeEAR99T3-20GLES-2T3-20GLCTG-2
M2H-0226ME-2Triple-Balanced MixersEConsult FactoryNot Recommended for New DesignEAR99T3-20GLES-2T3-20GLCTG-2

Table Of Contents

Rev: - | Copyright © 2022 - 2026 Marki Microwave LLC.

2

Port Configuration and Functions

Port Functions

PortFunctionDescriptionDC Equivalent
Circuit
IFIF The IF port is DC coupled to the diodes and AC matched to 50 Ohms from 1 to 10 GHz. Blocking capacitor is optional.Equivalent circuit for the IF
LOLO The LO port is DC coupled to ground and AC matched to 50 Ohms from 2 to 26.5 GHz. Blocking capacitor is optional.Equivalent circuit for the LO
RFRF The RF port is DC coupled to ground and AC matched to 50 Ohms from 2 to 26.5 GHz. Blocking capacitor is optional.Equivalent circuit for the RF

Rev: - | Copyright © 2022 - 2026 Marki Microwave LLC.

3

Specifications

Package Information

ParameterDetailsRating
WeightPackage name: E1g
Dimensions-15.24 x 8.13 mm
ParameterMinNominalMaxUnit
LO Input Power 13-16-

Rev: - | Copyright © 2022 - 2026 Marki Microwave LLC.

4

Electrical Specifications

Specifications guaranteed from -55 to +100°C, measured in a 50-Ohm system.

ParameterTest ConditionsMinTypMaxUnit
Conversion Loss LO/RF=20-26.5 GHz
IF=1-10 GHz
-1114.5dB
Conversion Loss LO/RF=20-26.5 GHz
IF=2-6 GHz
-9.513dB
Conversion Loss LO/RF=20-26.5 GHz
IF=2-8 GHz
-1013.5dB
Conversion Loss LO/RF=2-20 GHz
IF=1-10 GHz
-912.5dB
Conversion Loss LO/RF=2-20 GHz
IF=2-6 GHz
-7.511dB
Conversion Loss LO/RF=2-20 GHz
IF=2-8 GHz
-811.5dB
Input IP3 LO/RF=2-26.5 GHz
LO Drive level, M Diode Option=13-16 dBm
-18-dBm
Input P1dB LO/RF=2-26.5 GHz
LO Drive level, M Diode Option=13-16 dBm
-8-dBm
LO-IF Isolation LO/RF=2-26.5 GHz
-27-dB
LO-RF Isolation LO/RF=2-26.5 GHz
1528-dB
RF-IF Isolation LO/RF=2-26.5 GHz
-26-dB
IF Frequency Range -1-10GHz
RF Frequency Range -2-26.5GHz

Rev: - | Copyright © 2022 - 2026 Marki Microwave LLC.

5

Typical Performance Plots

Conversion Loss (dB) graph for M2H-0226ME-2
Relative IF Response (dB) graph for M2H-0226ME-2
LO to RF Isolation (dB) graph for M2H-0226ME-2
LO to IF Isolation (dB) graph for M2H-0226ME-2
RF to IF Isolation (dB) graph for M2H-0226ME-2
IF VSWR graph for M2H-0226ME-2
RF VSWR graph for M2H-0226ME-2
LO VSWR graph for M2H-0226ME-2

Rev: - | Copyright © 2022 - 2026 Marki Microwave LLC.

6

Mechanical Data

Outline Drawing

Outline Drawing

Rev: - | Copyright © 2022 - 2026 Marki Microwave LLC.

7