Device Overview

General Description

4-Way Wilkinson power dividers can be used for both in-phase power splitting and power combining applications. These power dividers are realized as a cascade of two 1:2 Wilkinson power dividers integrated into a single package. 4-Way Wilkinson power dividers feature the lowest insertion loss (ideally 4 dB 4-way splitting loss), excellent amplitude and phase balance, and high isolation across the entire operating band.

Photo of PD4-0126

Features

  • 1 to 26.5 GHz In-phase Power Splitting
  • Outstanding Output to Output Isolation
  • Outstanding Phase and Amplitude Balance

Applications

N/A

Functional Block Diagram

Block Diagram

Part Ordering Options

Part NumberDescriptionConnectorsGreen StatusProduct LifecycleExport Classification
PD4-01264-Way Wilkinson Power DividerStandard

REACH

RoHS

ReleasedEAR99

Table Of Contents

Revision History

Revision CodeRevision DateComment
E2020-10-01RoHS Assembly
F2025-12-17Power Handling Updated

Rev: F | Copyright © 2020, 2025 Marki Microwave LLC.

2

Port Configuration and Functions

Port Functions

PortFunctionConnector TypeDescriptionDC Equivalent
Circuit
InDivider Common Input SMAFWilkinson Divider Common Input-
Out 1Divider Output 1 SMAFRF divided output 1 of the Wilkinson divider.-
Out 2Divider Output 2 SMAFRF divided output 2 of the Wilkinson divider.-
Out 3Divider Output 3 SMAFRF divided output 3 of the Wilkinson divider.-
Out 4Divider Output 4 SMAFRF divided output 4 of the Wilkinson divider.-

Rev: F | Copyright © 2020, 2025 Marki Microwave LLC.

3

Specifications

Absolute Maximum Ratings

ParameterMaximum RatingUnit
RF Power Handling as a Power Combiner 1W
RF Power Handling as a Power Divider 10W

Package Information

ParameterDetailsRating
Weight-220g
Dimensions-120.4 × 67.3 mm

Rev: F | Copyright © 2020, 2025 Marki Microwave LLC.

4

Electrical Specifications

Specifications guaranteed from -55 to +100°C, measured in a 50Ω system.

ParameterTest ConditionsMinimum
Frequency
(GHz)
Maximum
Frequency
(GHz)
MinTypMaxUnit
Amplitude Balance -1 26.5-0.30.9dB
Excess Insertion Loss 1-1 26.5-1.5-dB
Isolation -1.6 26.515--dB
Isolation -1 1.61025-dB
Nominal Phase Shift -1 26.5-0-°
Nominal Power Splitting -1 26.5-6-dB
Phase Balance -1 26.5-310°
VSWR -1.8 26.5-1.5-

[1] Excess Insertion Loss = (Input Port to Common Port Insertion Loss) - 6dB

Rev: F | Copyright © 2020, 2025 Marki Microwave LLC.

5

Typical Performance Plots

Common port to output port insertion loss graph for PD4-0126
Return loss for output and common ports graph for PD4-0126
Amplitude balance between output ports graph for PD4-0126
Phase balance between output ports graph for PD4-0126
Isolation between output ports graph for PD4-0126

Rev: F | Copyright © 2020, 2025 Marki Microwave LLC.