Port Diagram
A top-down view of the MMD-3567L’s S package outline drawing is shown below. The MMD-3567L should only be used in the forward direction, with the input and output ports given in Port Functions.

Sales: 408-778-9952 | General: 408-778-4200 | Fax: 408-778-4300
Sales & Customer Support: [email protected]
Tech Support: [email protected]
The MMD-3567L is a MMIC millimeter wave doubler fabricated with GaAs Schottky diodes. This operates over a guaranteed 17.5 to 33.5 GHz input frequency range or a doubled output frequency range of 35 to 67 GHz. This doubler is a bandlimited version of the MMD-3580L. The sister die version, MMD-3580LCH, is capable of operating beyond 80GHz. Both the wire bondable die and connectorized units are available. For new designs, the MMD-3567LBH in our inline bullet housing package is the preferred package and offers improved performance over the MMD-3567LU.
| Part Number | Description | Package | Connectors | Green Status | Product Lifecycle | Export Classification |
|---|---|---|---|---|---|---|
| MMD-3567LU | GaAs MMIC Millimeter Wave Doubler | U | Standard | REACH RoHS | Released | EAR99 |
| Part Number | Description | Package | Connectors | Green Status | Product Lifecycle | Export Classification |
|---|---|---|---|---|---|---|
| MMD-3567LU | GaAs MMIC Millimeter Wave Doubler | U | Standard | REACH RoHS | Released | EAR99 |
MMD-3567LU
GaAs MMIC Millimeter Wave Doubler
| Revision Code | Revision Date | Comment |
|---|---|---|
| - | 2018-02-01 | Datasheet Initial Release |
| A | 2019-02-01 | Updated output return loss |
MMD-3567LU
GaAs MMIC Millimeter Wave Doubler
A top-down view of the MMD-3567L’s S package outline drawing is shown below. The MMD-3567L should only be used in the forward direction, with the input and output ports given in Port Functions.
| Port | Function | Connector Type | Description | DC Equivalent Circuit |
|---|---|---|---|---|
| GND | Ground | - | U package ground provided through metal housing and outer coax conductor. | |
| Port 1 | Input | 2.92F | Input 1x Frequency Port. Port 1 is DC open for the U package. | |
| Port 2 | Output | 1.85F | 2x Input Frequency output port. Port 2 is DC open for the U package. |
MMD-3567LU
GaAs MMIC Millimeter Wave Doubler
The Absolute Maximum Ratings indicate limits beyond which damage may occur to the device. If these limits are exceeded, the device may be inoperable or have a reduced lifetime.
| Parameter | Maximum Rating | Unit |
|---|---|---|
| Maximum Operating Temperature | 100 | °C |
| Maximum Storage Temperature | 125 | °C |
| Minimum Operating Temperature | -55 | °C |
| Minimum Storage Temperature | -65 | °C |
| Parameter | Details | Rating |
|---|---|---|
| Weight | Package name: U | 10g |
| Dimensions | - | 14.22 x 13.21mm |
The Recommended Operating Conditions indicate the limits, inside which the device should be operated, to guarantee the performance given in Electrical Specifications Operating outside these limits may not necessarily cause damage to the device, but the performance may degrade outside the limits of the electrical specifications. For limits, above which damage may occur, see Absolute Maximum Ratings.
| Parameter | Min | Nominal | Max | Unit |
|---|---|---|---|---|
| Ambient Temperature | -55 | 25 | 100 | °C |
| Input Power | 7 | - | 11 | dBm |
MMD-3567LU
GaAs MMIC Millimeter Wave Doubler
The Recommended Operating Conditions indicate the limits, inside which the device should be operated, to guarantee the performance given in Electrical Specifications Operating outside these limits may not necessarily cause damage to the device, but the performance may degrade outside the limits of the electrical specifications. For limits, above which damage may occur, see Absolute Maximum Ratings.
| Parameter | Test Conditions | Minimum Frequency (GHz) | Maximum Frequency (GHz) | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|---|
| Conversion Loss | Second Harmonic Output | - | - | - | 11 | 15 | dB |
| Input Frequency Range | - | - | - | 17.5 | - | 33.5 | GHz |
| Input Power | - | - | - | 7 | - | 11 | dBm |
| Isolation, 1F 1 | Input = 17.5 - 40 GHz Output = 17.5 - 40 GHz | - | - | - | 47.7 | - | dB |
| Isolation, 3F 2 | Input = 17.5 – 22.3 GHz Output = 52.5 - 67 GHz | - | - | - | 54.4 | - | dB |
| Isolation, 4F 3 | Input = 15 – 16.8 GHz Output = 60 - 67 GHz | - | - | - | 31 | - | dB |
| Output Frequency Range | - | - | - | 35 | - | 67 | GHz |
| Suppression, 1F 4 | Input = 17.5 - 40 GHz Output = 17.5 - 40 GHz | - | - | - | 38 | - | dBc |
| Suppression, 3F 5 | Input = 17.5 – 22.3 GHz Output = 52.5 - 67 GHz | - | - | - | 44 | - | dBc |
| Suppression, 4F 6 | Input = 15 – 16.8 GHz Output = 60 - 67 GHz | - | - | - | 21 | - | dBc |
| Parameter | Test Conditions | Minimum Frequency (GHz) | Maximum Frequency (GHz) | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|---|
| Conversion Loss | Second Harmonic Output | - | - | - | 11 | 15 | dB |
| Input Frequency Range | - | - | - | 17.5 | - | 33.5 | GHz |
| Input Power | - | - | - | 7 | - | 11 | dBm |
| Isolation, 1F 1 | Input = 17.5 - 40 GHz Output = 17.5 - 40 GHz | - | - | - | 47.7 | - | dB |
| Isolation, 3F 2 | Input = 17.5 – 22.3 GHz Output = 52.5 - 67 GHz | - | - | - | 54.4 | - | dB |
| Isolation, 4F 3 | Input = 15 – 16.8 GHz Output = 60 - 67 GHz | - | - | - | 31 | - | dB |
| Output Frequency Range | - | - | - | 35 | - | 67 | GHz |
| Suppression, 1F 4 | Input = 17.5 - 40 GHz Output = 17.5 - 40 GHz | - | - | - | 38 | - | dBc |
| Suppression, 3F 5 | Input = 17.5 – 22.3 GHz Output = 52.5 - 67 GHz | - | - | - | 44 | - | dBc |
| Suppression, 4F 6 | Input = 15 – 16.8 GHz Output = 60 - 67 GHz | - | - | - | 21 | - | dBc |
[1][2][3] Isolation is defined as the harmonic power relative to the 1F fundamental input power.
[4][5][6] Suppressions and isolations measured with an input source with >70dBc (relative to fundamental input) harmonic suppression. Suppression is defined as the harmonic power relative to the 2F doubled output power
MMD-3567LU
GaAs MMIC Millimeter Wave Doubler
MMD-3567LU
GaAs MMIC Millimeter Wave Doubler
MMD-3567LU
GaAs MMIC Millimeter Wave Doubler