Rev: - | Copyright © 2019 Marki Microwave LLC.

General Description

MT3L-0113H is a GaAs MMIC triple balanced mixer with high dynamic range and low conversion loss. This mixer belongs to the T3 family which offers high IP3, P1dB, and broad operating bandwidths for applications in the S, C and X bands. MT3L-0113H is the monolithic cousin of the MT3-0113HCQG and sister of the MT3H-0113HCH targeted towards lower IF applications in a small footprint. The MT3L-0113H is available as both wire bondable die and a connectorized module.

Features

  • Low IF band
  • Broad, overlapping RF/LO & IF bands
  • High >+30 dBm IP3

Functional Block Diagram

Block Diagram

Electrical Performance Summary

ParameterTypUnit
Conversion Loss 10.5dB
RF Frequency Range 1.5 to 13GHz
Input IP3 31dBm
LO Input Power 15 to 25dBm
IF Frequency Range 0.25 to 5GHz

Summary only – refer to the Electrical Specifications, Absolute Maximum Ratings, and Recommended Operating Range tables for complete details.

Part Ordering Options

Part NumberDescriptionPackageConnectorsGreen StatusProduct LifecycleExport Classification
MT3L-0113HSGaAs MMIC High Dynamic Range MixerSStandard

REACH

RoHS

ReleasedEAR99

Table Of Contents

Typical Performance Plots

Conversion Loss: 0.75 GHz IF, Highside LO (dB) graph for MT3L-0113HS
Conversion Loss: 0.75 GHz IF, Highside Square Wave LO (dB) graph for MT3L-0113HS
Configuration A Conversion Loss vs. LO Power: 0.75 GHz IF (dB) graph for MT3L-0113HS
Configuration B Conversion Loss vs. LO Power: 0.75 GHz IF (dB) graph for MT3L-0113HS
Relative IF Response (dB) graph for MT3L-0113HS
Relative IF Response (dB) graph for MT3L-0113HS
Conversion Loss: 4 GHz IF, Highside Sine Wave LO (dB) graph for MT3L-0113HS
Configuration A Conversion Loss vs. LO Power: 4GHz IF (dB) graph for MT3L-0113HS
Configuration B Conversion Loss vs. LO Power: 4 GHz IF (dB) graph for MT3L-0113HS
LO to RF Isolation (dB) graph for MT3L-0113HS
LO to IF Isolation (dB) graph for MT3L-0113HS
RF to IF Isolation (dB) graph for MT3L-0113HS
RF Return Loss (dB) graph for MT3L-0113HS
IF Return Loss (dB) graph for MT3L-0113HS
LO Return Loss (dB) graph for MT3L-0113HS

Typical Performance Plots: IP3, Sine Wave LO

Input IP3: +20 dBm Sine Wave LO (dBm) graph for MT3L-0113HS
Output IP3: +20 dBm Sine Wave LO (dBm) graph for MT3L-0113HS
Configuration A Input IP3 vs LO Power: Sine Wave LO (dBm) graph for MT3L-0113HS
Configuration A Output IP3 vs LO Power: Sine Wave LO (dBm) graph for MT3L-0113HS
Configuration B Input IP3 vs LO Power: Sine Wave LO (dBm) graph for MT3L-0113HS
Configuration B Output IP3 vs LO Power: Sine Wave LO (dBm) graph for MT3L-0113HS

Typical Performance Plots: IP3, Square Wave LO

Input IP3: +20 dBm Square Wave LO (dBm) graph for MT3L-0113HS
Output IP3: +20 dBm Square Wave LO (dBm) graph for MT3L-0113HS
Configuration A Input IP3 vs LO Power: Square Wave LO (dBm) graph for MT3L-0113HS
Configuration A Output IP3 vs LO Power: Square Wave LO (dBm) graph for MT3L-0113HS
Configuration B Input IP3 vs LO Power: Square Wave LO (dBm) graph for MT3L-0113HS
Configuration B Output IP3 vs LO Power: Square Wave LO (dBm) graph for MT3L-0113HS

Typical Performance Plots: LO Harmonic Isolation

Even LO Harmonic to RF Isolation (dB) graph for MT3L-0113HS
Even LO Harmonic to IF Isolation (dB) graph for MT3L-0113HS
Odd LO Harmonic to RF Isolation (dB) graph for MT3L-0113HS
Odd LO Harmonic to IF Isolation (dB) graph for MT3L-0113HS
2RF x 2LO Spurious Suppression (dBc) -10 dBm IF Input graph for MT3L-0113HS
2RF x 2LO Spurious Suppression (dBc) -10 dBm IF Input graph for MT3L-0113HS
2IF x 1LO Spurious Suppression (dBc) -10 dBm IF input graph for MT3L-0113HS
2IF x 1LO Spurious Suppression (dBc) -10 dBm IF input graph for MT3L-0113HS

Specifications

Electrical Specifications

The electrical specifications apply at TA=+25°C in a 50Ω system. Typical data shown is for the connectorized S package mixer used with a +20 dBm sine wave LO. Min and Max limits apply only to our connectorized units and are guaranteed at TA=+25°C.

ParameterPort ConfigurationTest ConditionsMinimum
Frequency
(GHz)
Maximum
Frequency
(GHz)
MinTypMaxUnit
Conversion Loss 1ARF/LO = 1.5 - 13 GHz
I = 0.25- 0.75 GHz
1.5 13-10.5-dB
Conversion Loss 2ARF/LO = 1.5 - 13 GHz
I = 0.75- 5 GHz
1.5 13-9.5-dB
Conversion Loss 3ARF/LO = 1.5 - 13 GHz
I = 0.75 GHz
1.5 13-8.511.5dB
Input IP3 ARF/LO = 1.5 - 13 GHz
I = 0.75 GHz
1.5 13-31-dBm
Input P1dB 4A-- --20-dBm
Conversion Loss 5BRF/LO = 1.5 - 13 GHz
I = 0.25- 0.75 GHz
1.5 13-11-dB
Conversion Loss 6BRF/LO = 1.5 - 13 GHz
I = 0.75- 5 GHz
1.5 13-11-dB
Conversion Loss 7BRF/LO = 1.5 - 13 GHz
I = 0.75 GHz
1.5 13-1013dB
Input IP3 BRF/LO = 1.5 - 13 GHz
I = 0.75 GHz
1.5 13-31-dBm
Input P1dB 8B-- --20-dBm
IF Frequency Range --- -0.25-5GHz
LO Frequency Range --- -1.5-13GHz
LO-IF Isolation -IF/LO = 1.5 - 13 GHz
1.5 13-41-dB
LO-RF Isolation -RF/LO = 1.5 - 13 GHz
1.5 13-43-dB
Noise Figure 9-RF/LO = 1.5 - 13 GHz
I = 0.75 GHz
1.5 13-8.5-dB
RF Frequency Range --- -1.5-13GHz
RF-IF Isolation -RF/IF = 1.5 - 13 GHz
1.5 13-39-dB

[1][2][3][5][6][7] Measured as a down converter to a fixed 750 MHz IF. Unless otherwise stated, frequency conversion done using a highside LO.

[4][8] P1dB is measured using a +23 dBm square wave LO.

[9] Mixer Noise Figure typically measures within 0.5 dB of conversion loss for IF frequencies greater than 5 MHz.

The Recommended Operating Conditions indicate the limits, inside which the device should be operated, to guarantee the performance given in Electrical Specifications Operating outside these limits may not necessarily cause damage to the device, but the performance may degrade outside the limits of the electrical specifications. For limits, above which damage may occur, see Absolute Maximum Ratings.

ParameterMinNominalMaxUnit
Ambient Temperature -5525100°C
LO Input Power 15-25dBm

Absolute Maximum Ratings

The Absolute Maximum Ratings indicate limits beyond which damage may occur to the device. If these limits are exceeded, the device may be inoperable or have a reduced lifetime.

ParameterMaximum RatingUnit
Maximum Operating Temperature 100°C
Maximum Storage Temperature 125°C
Minimum Operating Temperature -55°C
Minimum Storage Temperature -65°C
Port 1 DC Current 150mA
Port 2 DC Current 150mA
Power Handling, at any Port 33dBm

Package Information

ParameterDetailsRating
ESD250 to < 500 VoltsHBM Class 1A
WeightPackage name: S10g
Dimensions-14.22 x 13.21 mm

Sequencing Requirements

There is no requirement to apply power to the ports in a specific order. However, it is recommended to provide a 50Ω termination to each port before applying power. This is a passive diode mixer that requires no DC bias.

Port Configuration and Functions

Port Diagram

The MT3L-0113H has the input and output ports given in Port Functions. The MT3L-0113H can be used in either an up or down conversion. For configuration A, input the LO into port 1, use port 3 for the RF, and port 2 for the IF. For configuration B, input the LO into port 3, use port 1 for the RF, and port 2 for the IF.

Diagram of the port configuration for MT3L-0113HS

Port Functions

Configuration A

PortFunctionConnector TypeDescriptionDC Equivalent
Circuit
Port 2IF SMAFPort 2 is DC open for the CH and S package.Equivalent circuit for the IF
Port 1LO SMAFPort 1 is DC short for the CH and S packages.Equivalent circuit for the LO
Port 3RF SMAFPort 3 is DC short for the CH and S packages.Equivalent circuit for the RF
GNDGround -S package ground provided through metal housing and outer coax conductor.Equivalent circuit for the Ground

Configuration B

PortFunctionConnector TypeDescriptionDC Equivalent
Circuit
GNDGround -S package ground provided through metal housing and outer coax conductor.Equivalent circuit for the Ground
Port 1RF SMAFPort 1 is DC short for the CH and S packages.Equivalent circuit for the RF
Port 3LO SMAFPort 3 is DC short for the CH and S packages.Equivalent circuit for the LO
Port 2IF SMAFPort 2 is DC open for the CH and S package.Equivalent circuit for the IF

Spur Table

Typical Spurious Performance: Down-Conversion

Typical spurious data is provided by selecting RF and LO frequencies (± m*LO ± n*RF) within the RF/LO bands, to create a spurious output within the IF band. The mixer is swept across the full spurious band and the mean is calculated. The numbers shown in the table below are for a -10 dBm RF input. Spurious suppression is scaled for different RF power levels by (n-1), where “n” is the RF spur order. For example, the 2RF x 2LO spur is 63 dBc for a -10 dBm input, so a -20 dBm RF input creates a spur that is (2-1) x (-10 dB) lower, or 73 dBc.

Typical Down Conversion Spurious Suppression Config a B Sine Wave Lo

Typical Down Conversion Spurious Suppression Config a B Square Wave Lo

Typical Spurious Performance: Up-Conversion

Typical spurious data is taken by mixing an input within the IF band, with LO frequencies (± m*LO ± n*IF), to create a spurious output within the RF output band. The mixer is swept across the full spurious output band and the mean is calculated. The numbers shown in the table below are for a -10 dBm IF input. Spurious suppression is scaled for different IF input power levels by (n-1), where “n” is the IF spur order. For example, the 2IFx1LO spur is typically 64 dBc for a -10 dBm input with a sine-wave LO, so a -20 dBm IF input creates a spur that is (2-1) x (-10 dB) lower, or 74 dBc.

Typical up Conversion Spurious Suppression Config a B Sine Wave LoTypical up Conversion Spurious Suppression Config a B Square Wave Lo

Mechanical Data

Outline Drawing

Download : Outline 2D Drawing Outline 3D Drawing Outline 3D STP

Outline Drawing

Revision History

Revision CodeRevision DateComment
-2019-01-01Datasheet Initial Release

DISCLAIMER

MARKI MICROWAVE, LLC., (“MARKI”) PROVIDES TECHNICAL SPECIFICATIONS AND DATA (INCLUDING DATASHEETS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, AND OTHER INFORMATION AND RESOURCES “AS IS” AND WITH ALL FAULTS. MARKI DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT.

These resources are intended for developers skilled in the art designing with Marki products. You are solely responsible for (1) selecting the appropriate products for your application, (2) designing, validating, and testing your application, and (3) ensuring your application meets applicable standards and other requirements. Marki makes no guarantee regarding the suitability of its products for any particular purpose, nor does Marki assume any liability whatsoever arising out of your use or application of any Marki product.

Marki grants you permission to use these resources only for development of an application that uses Marki products. Other reproduction or use of these resources is strictly prohibited. No license is granted to any other Marki intellectual property or to any third-party intellectual property. Marki reserves the right to make changes to the product(s) or information contained herein without notice.

MARKI MICROWAVE, M wave logo, FastSwitch, and T3 MIXER are trademarks or registered trademarks of Marki Microwave, LLC. All other trademarks used are the property of their respective owners.

© 2019, Marki Microwave, LLC