Rev: A | Copyright © 2017, 2019 Marki Microwave LLC.

General Description

The MT3H-0113L is a triple balanced passive diode mixer offering high dynamic range, low conversion loss, and excellent repeatability. As with all T3 mixers, this mixer offers unparalleled nonlinear performance in terms of IIP3, P1dB, and spurious performance with a flexible LO drive requirement from +7 dBm to +15 dBm. RF, LO, and IF ports are all operated single ended due to integrated baluns. The MT3H-0113L is available as a wire bondable chip or an SMA connectorized package. The MT3H-0113L is a superior alternative to Marki Microwave carrier and packaged T3 mixers. If >+16dBm LO power is available, the higher barrier MT3H-0113H is recommended.

Features

  • Broadband, Overlapping RF, LO and IF
  • RoHS Compliant
  • Square-Wave LO delivers Industry-Leading Spurious, IP3, and P1dB Performance

Functional Block Diagram

Block Diagram

Electrical Performance Summary

ParameterTypUnit
Conversion Loss 8dB
RF Frequency Range 1.5 to 13GHz
Input IP3 20dBm
LO Input Power 7 to 15-
IF Frequency Range 0.8 to 8.5GHz

Summary only – refer to the Electrical Specifications, Absolute Maximum Ratings, and Recommended Operating Range tables for complete details.

Part Ordering Options

Part NumberDescriptionPackageConnectorsGreen StatusProduct LifecycleExport Classification
MT3H-0113LSGaAs MMIC High Dynamic Range MixerSStandard

REACH

RoHS

ReleasedEAR99

Table Of Contents

Typical Performance Plots

Conversion Loss: 1 GHz IF, Highside LO (dB) graph for MT3H-0113LS
Conversion Loss: 1 GHz IF, Highside Square Wave LO (dB) graph for MT3H-0113LS
Configuration A Conversion Loss vs. LO Power (dB) graph for MT3H-0113LS
Configuration B Conversion Loss vs. LO Power (dB) graph for MT3H-0113LS
Relative IF Response (dB) graph for MT3H-0113LS
Relative IF Response (dB) graph for MT3H-0113LS
Conversion Loss: 4 GHz IF, Highside Sine Wave LO (dB) graph for MT3H-0113LS
Conversion Loss: 4 GHz IF, Highside Square Wave LO (dB) graph for MT3H-0113LS
Configuration A Conversion Loss vs. LO Power: 4GHz IF (dB) graph for MT3H-0113LS
Configuration B Conversion Loss vs. LO Power: 4 GHz IF (dB) graph for MT3H-0113LS
LO to RF Isolation (dB) graph for MT3H-0113LS
LO to IF Isolation (dB) graph for MT3H-0113LS
RF to IF Isolation (dB) graph for MT3H-0113LS
RF Return Loss (dB) graph for MT3H-0113LS
IF Return Loss (dB) graph for MT3H-0113LS
LO Return Loss (dB) graph for MT3H-0113LS
Input IP3: +15dBm Sine Wave LO (dBm) graph for MT3H-0113LS
Input IP3: +17dBm Square Wave LO (dBm) graph for MT3H-0113LS
Configuration A Input IP3 vs LO Power: Sine Wave LO (dBm) graph for MT3H-0113LS
Configuration A Input IP3 vs LO Power: Square Wave LO (dBm) graph for MT3H-0113LS
Configuration B Input IP3 vs LO Power: Sine Wave LO (dBm) graph for MT3H-0113LS
Configuration B Input IP3 vs LO Power: Square Wave LO (dBm) graph for MT3H-0113LS
Output IP3: +15dBm Sine Wave LO (dBm) graph for MT3H-0113LS
Output IP3: +17dBm Square Wave LO (dBm) graph for MT3H-0113LS
Configuration A Output IP3 vs LO Power: Sine Wave LO (dBm) graph for MT3H-0113LS
Configuration A Output IP3 vs LO Power: Square Wave LO (dBm) graph for MT3H-0113LS
Configuration B Output IP3 vs LO Power: Sine Wave LO (dBm) graph for MT3H-0113LS
Configuration B Output IP3 vs LO Power: Square Wave LO (dBm) graph for MT3H-0113LS
Input 1 dB Compression Point: 1 GHz IF, 5 GHz LO (dB) graph for MT3H-0113LS
Output 1 dB Compression Point: 1 GHz IF, 5 GHz LO (dB) graph for MT3H-0113LS
Even LO Harmonic to RF Isolation (dB) graph for MT3H-0113LS
Even LO Harmonic to IF Isolation (dB) graph for MT3H-0113LS
Odd LO Harmonic to RF Isolation (dB) graph for MT3H-0113LS
Odd LO Harmonic to IF Isolation (dB) graph for MT3H-0113LS
2RF x 2LO Spurious Suppression (dBc) -10 dBm RF Input graph for MT3H-0113LS
2RF x 2LO Spurious Suppression (dBc) -10 dBm RF Input graph for MT3H-0113LS
2IF x 1LO Spurious Suppression (dBc) -10 dBm IF input graph for MT3H-0113LS
2IF x 1LO Spurious Suppression (dBc) -10 dBm IF input graph for MT3H-0113LS

Specifications

Electrical Specifications

Specifications guaranteed from -55 to +100°C, measured in a 50Ω system. All bare die are 100% DC tested and 100% visually inspected. RF testing is performed on a sample basis to verify conformance to datasheet guaranteed specifications. Consult factory for more information.

ParameterPort ConfigurationTest ConditionsMinimum
Frequency
(GHz)
Maximum
Frequency
(GHz)
MinTypMaxUnit
Input IP3 1ALO/RF=1.5-13 GHz
IF=0.8-8.5 GHz
LO drive level=7-15 dBm
1.5 13-20-dBm
Input IP3 2BLO/RF=1.5-13 GHz
IF=0.8-8.5 GHz
LO drive level=7-15 dBm
1.5 13-22-dBm
Conversion Loss 3-LO/RF=1.5-13 GHz
IF=0.8-1 GHz
LO drive level=15 dBm
1.5 13-811dB
Conversion Loss 4-LO/RF=1.5-13 GHz
IF=1-8.85 GHz
LO drive level=15 dBm
1.5 13-11.5-dB
IF Frequency Range --- -0.8-8.5GHz
LO Frequency Range --- -1.5-13GHz
LO-RF Isolation --1 13-43-dB
RF Frequency Range --- -1.5-13GHz

[1][2] IP3 depends on LO drive conditions, see plots for more details.

[3][4] Measured Conversion Loss measured at 1 GHz fixed IF.

ParameterMinNominalMaxUnit
LO Input Power 7-15-

Absolute Maximum Ratings

ParameterMaximum RatingUnit
Maximum Operating Temperature 100°C
Maximum Storage Temperature 125°C
Minimum Operating Temperature -55°C
Minimum Storage Temperature -65°C
RF Power Handling (RF+LO) 30dBm

Package Information

ParameterDetailsRating
Dimensions-14.22 x 13.21mm

Port Configuration and Functions

Port Diagram

Diagram of the port configuration for MT3H-0113LS

Port Functions

Configuration A

PortFunctionConnector TypeDescriptionDC Equivalent
Circuit
Port 2IF SMAFPort 2 is DC open. Blocking capacitor is optional.Equivalent circuit for the IF
Port 3RF SMAFPort 3 is DC short and AC matched to 50 Ω from 0.8 to 13 GHz. Blocking capacitor is optional.Equivalent circuit for the RF
Port 1LO SMAFPort 1 is DC short and AC matched to 50 Ω from 0.8 to 13 GHz. Blocking capacitor is optional.Equivalent circuit for the LO

Configuration B

PortFunctionConnector TypeDescriptionDC Equivalent
Circuit
Port 1RF SMAFPort 1 is DC short and AC matched to 50 Ω from 0.8 to 13 GHz. Blocking capacitor is optional.Equivalent circuit for the RF
Port 3LO SMAFPort 3 is DC short and AC matched to 50 Ω from 0.8 to 13 GHz. Blocking capacitor is optional.Equivalent circuit for the LO
Port 2IF SMAFPort 2 is DC open. Blocking capacitor is optional.Equivalent circuit for the IF

Spur Table

Downconversion Spurious Suppression

Spurious data is taken by selecting RF and LO frequencies (+mLO+nRF) within the RF/LO bands, to create a spurious output within the IF band. The mixer is swept across the full spurious band and the mean is calculated. The numbers shown in the table below are for a -10 dBm RF input. Spurious suppression is scaled for different RF power levels by (n-1), where “n” is the RF spur order. For example, the 2RFx2LO spur is 57 dBc for the A configuration for a -10 dBm input, so a -20 dBm RF input creates a spur that is (2-1) x (-10 dB) dB lower, or 67 dBc.

M T3 H 0113 Ls Typical Down Conversion Spurious Suppression

M T3 H 0113 Ls Typical Down Conversion Spurious  Suppression

Upconversion Spurious Suppression

Spurious data is taken by mixing an input within the IF band, with LO frequencies (+mLO+nIF), to create a spurious output within the RF output band. The mixer is swept across the full spurious output band and the mean is calculated. The numbers shown in the table below are for a -10 dBm IF input. Spurious suppression is scaled for different IF input power levels by (n-1), where “n” is the IF spur order. For example, the 2IFx1LO spur is typically 62 dBc for the A configuration for a -10 dBm input, so a -20 dBm IF input creates a spur that is (2-1) x (-10 dB) dB lower, or 72 dBc.

M T3 H 0113 Ls Typical up Conversion Spurious Suppression

M T3 H 0113 Ls Typical up Conversion Spurious  Suppression

Operation

Application Information

M T3 H 0113 Ls App Ckt

Configuration A/B refer to the same part number (MT3H-0113L) used in one of two different ways for optimal spurious performance. For the lowest conversion loss, use the mixer in Configuration A (port 1 as the LO input, port 3 as the RF input or output). If you need to use a lower LO drive, use the mixer in Configuration B (port 1 as the RF input or output, port 3 as the LO input). For optimal spurious suppression, experimentation or simulation is required to choose between Configuration A and B.

Mechanical Data

Outline Drawing

Download : Outline 2D Drawing Outline 3D Drawing Outline 3D STP

Outline Drawing

Revision History

Revision CodeRevision DateComment
-2017-01-01Initial Release
A2019-01-01Revised square wave LO IP3 plots. End note 5 updated to reflect new test condition.

Notes

  1. Mixer Conversion Loss Plot IF frequency is 1 GHz unless otherwise specified.
  2. Mixer Noise Figure typically measures within 0.5 dB of conversion loss for IF frequencies greater than 5 MHz.
  3. Conversion Loss typically degrades less than 0.5 dB at +100°C and improves less than 0.5 dB at -55°C.
  4. Unless otherwise specified, data is taken with highside, +15 dBm sine wave LO drive.
  5. Square wave LO generated using 2x ADM1-0026PA with +10 dBm input into the first stage. LO Power reported in plots is of the fundamental tone only. Square wave LO power in plots is stepped down using broadband DC-40 GHz attenuators.
  6. Specifications are subject to change without notice. Contact Marki Microwave for the most recent specifications and data sheets.
  7. Catalog mixer circuits are continually improved. Configuration control requires custom mixer model numbers and specifications.

Note: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.

DISCLAIMER

MARKI MICROWAVE, LLC., (“MARKI”) PROVIDES TECHNICAL SPECIFICATIONS AND DATA (INCLUDING DATASHEETS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, AND OTHER INFORMATION AND RESOURCES “AS IS” AND WITH ALL FAULTS. MARKI DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT.

These resources are intended for developers skilled in the art designing with Marki products. You are solely responsible for (1) selecting the appropriate products for your application, (2) designing, validating, and testing your application, and (3) ensuring your application meets applicable standards and other requirements. Marki makes no guarantee regarding the suitability of its products for any particular purpose, nor does Marki assume any liability whatsoever arising out of your use or application of any Marki product.

Marki grants you permission to use these resources only for development of an application that uses Marki products. Other reproduction or use of these resources is strictly prohibited. No license is granted to any other Marki intellectual property or to any third-party intellectual property. Marki reserves the right to make changes to the product(s) or information contained herein without notice.

MARKI MICROWAVE, M wave logo, FastSwitch, and T3 MIXER are trademarks or registered trademarks of Marki Microwave, LLC. All other trademarks used are the property of their respective owners.

© 2017, 2019, Marki Microwave, LLC