Rev: A | Copyright © 2017, 2019 Marki Microwave LLC.

General Description

The MT3H-0113H is a triple balanced passive diode mixer offering high dynamic range, low conversion loss, and excellent repeatability. As with all T3 mixers, this mixer offers unparalleled nonlinear performance in terms of IIP3, P1dB, and spurious performance with a flexible LO drive requirement from +16 dBm to +24 dBm. RF, LO, and IF ports are all operated single ended due to integrated baluns. The MT3H-0113H is available as a wire bondable chip or an SMA connectorized package. The MT3H-0113H is a superior alternative to Marki Microwave carrier and packaged T3 mixers.

Features

  • Broadband, Overlapping RF, LO and IF
  • RoHS Compliant
  • Square-Wave LO delivers Industry-Leading Spurious, IP3, and P1dB Performance

Functional Block Diagram

Block Diagram

Electrical Performance Summary

ParameterTypUnit
Conversion Loss 8dB
RF Frequency Range 1.5 to 13GHz
Input IP3 29dBm
LO Input Power 16 to 24-
IF Frequency Range 0.8 to 8.5GHz

Summary only – refer to the Electrical Specifications, Absolute Maximum Ratings, and Recommended Operating Range tables for complete details.

Part Ordering Options

Part NumberDescriptionPackageConnectorsGreen StatusProduct LifecycleExport Classification
MT3H-0113HSGaAs MMIC High Dynamic Range MixerSStandard

REACH

RoHS

ReleasedEAR99

Table Of Contents

Typical Performance Plots

Conversion Loss: 1 GHz IF, Highside LO (dB) graph for MT3H-0113HS
Conversion Loss: 1 GHz IF, Highside Square Wave LO (dB) graph for MT3H-0113HS
Configuration A Conversion Loss vs. LO Power (dB) graph for MT3H-0113HS
Configuration B Conversion Loss vs. LO Power (dB) graph for MT3H-0113HS
Relative IF Response (dB) graph for MT3H-0113HS
Relative IF Response (dB) graph for MT3H-0113HS
Conversion Loss: 4 GHz IF, Highside Sine Wave LO (dB) graph for MT3H-0113HS
Configuration A Conversion Loss vs. LO Power: 4GHz IF (dB) graph for MT3H-0113HS
Configuration B Conversion Loss vs. LO Power: 4 GHz IF (dB) graph for MT3H-0113HS
LO to RF Isolation (dB) graph for MT3H-0113HS
LO to IF Isolation (dB) graph for MT3H-0113HS
RF to IF Isolation (dB) graph for MT3H-0113HS
RF Return Loss (dB) graph for MT3H-0113HS
IF Return Loss (dB) graph for MT3H-0113HS
LO Return Loss (dB) graph for MT3H-0113HS
Input IP3: +20 dBm Sine Wave LO (dBm) graph for MT3H-0113HS
Input IP3: +23dBm Square Wave LO (dBm) graph for MT3H-0113HS
Configuration A Input IP3 vs LO Power: Sine Wave LO (dBm) graph for MT3H-0113HS
Configuration A Input IP3 vs LO Power: Square Wave LO (dBm) graph for MT3H-0113HS
Configuration B Input IP3 vs LO Power: Sine Wave LO (dBm) graph for MT3H-0113HS
Configuration B Input IP3 vs LO Power: Square Wave LO (dBm) graph for MT3H-0113HS
Configuration A Output IP3 vs LO Power: Sine Wave LO (dBm) graph for MT3H-0113HS
Configuration A Output IP3 vs LO Power: Square Wave LO (dBm) graph for MT3H-0113HS
Configuration B Output IP3 vs LO Power: Sine Wave LO (dBm) graph for MT3H-0113HS
Configuration B Output IP3 vs LO Power: Square Wave LO (dBm) graph for MT3H-0113HS
Even LO Harmonic to RF Isolation (dB) graph for MT3H-0113HS
Even LO Harmonic to IF Isolation (dB) graph for MT3H-0113HS
Odd LO Harmonic to RF Isolation (dB) graph for MT3H-0113HS
Odd LO Harmonic to IF Isolation (dB) graph for MT3H-0113HS
2RF x 2LO Spurious Suppression (dBc) -10 dBm RF Input graph for MT3H-0113HS
2RF x 2LO Spurious Suppression (dBc) -10 dBm RF Input graph for MT3H-0113HS
2IF x 1LO Spurious Suppression (dBc) -10 dBm IF input graph for MT3H-0113HS
2IF x 1LO Spurious Suppression (dBc) -10 dBm IF input graph for MT3H-0113HS

Specifications

Electrical Specifications

Specifications guaranteed from -55 to +100°C, measured in a 50Ω system. All bare die are 100% DC tested and 100% visually inspected. RF testing is performed on a sample basis to verify conformance to datasheet guaranteed specifications.

ParameterPort ConfigurationTest ConditionsMinimum
Frequency
(GHz)
Maximum
Frequency
(GHz)
MinTypMaxUnit
Conversion Loss 1ALO/RF=1.5-13 GHz
IF=0.8-1 GHz
LO Drive level=20 dBm
1.5 13-811dB
IF Frequency Range A-- -0.8-8.5GHz
LO Frequency Range A-- -1.5-13GHz
RF Frequency Range A-- -1.5-13GHz
Conversion Loss 2BLO/RF=1.5-13 GHz
IF=0.8-1 GHz
LO Drive level=20 dBm
1.5 13-11.5-dB
Input IP3 3BLO/RF=1.5-13 GHz
IF=0.8-8.5 GHz
LO Drive level=16-24 dBm
1.5 13-29-dBm
Input IP3 4BLO/RF=1.5-13 GHz
IF=0.8-8.5 GHz
LO Drive level=16-24 dBm
1.5 13-28-dBm
LO-RF Isolation --1 13-37-dB

[1][2] Measured Conversion Loss measured at 1 GHz fixed IF.

[3][4] IP3 depends on LO drive conditions, see plots for more details.

ParameterMinNominalMaxUnit
LO Input Power 16-24-

Absolute Maximum Ratings

ParameterMaximum RatingUnit
Maximum Operating Temperature 100°C
Maximum Storage Temperature 125°C
Minimum Operating Temperature -55°C
Minimum Storage Temperature -65°C
RF Power Handling (RF+LO) 130dBm

[1] H-Version

Package Information

ParameterDetailsRating
Dimensions-14.22 x 13.21mm

Port Configuration and Functions

Port Diagram

Diagram of the port configuration for MT3H-0113HS

Port Functions

Configuration A

PortFunctionConnector TypeDescriptionDC Equivalent
Circuit
Port 2IF SMAFPort 2 is DC open. Blocking capacitor is optional.Equivalent circuit for the IF
Port 1LO SMAFPort 1 is DC short and AC matched to 50 Ω from 0.8 to 13 GHz. Blocking capacitor is optional.Equivalent circuit for the LO
Port 3RF SMAFPort 3 is DC short and AC matched to 50 Ω from 0.8 to 13 GHz. Blocking capacitor is optional.Equivalent circuit for the RF

Configuration B

PortFunctionConnector TypeDescriptionDC Equivalent
Circuit
Port 1RF SMAFPort 1 is DC short and AC matched to 50 Ω from 0.8 to 13 GHz. Blocking capacitor is optional.Equivalent circuit for the RF
Port 3LO SMAFPort 3 is DC short and AC matched to 50 Ω from 0.8 to 13 GHz. Blocking capacitor is optional.Equivalent circuit for the LO
Port 2IF SMAFPort 2 is DC open. Blocking capacitor is optional.Equivalent circuit for the IF

Spur Table

Downconversion Spurious Suppression

Spurious data is taken by selecting RF and LO frequencies (+mLO+nRF) within the RF/LO bands, to create a spurious output within the IF band. The mixer is swept across the full spurious band and the mean is calculated. The numbers shown in the table below are for a -10 dBm RF input. Spurious suppression is scaled for different RF power levels by (n-1), where “n” is the RF spur order. For example, the 2RFx2LO spur is 60 dBc for the A configuration for a -10 dBm input, so a -20 dBm RF input creates a spur that is (2-1) x (-10 dB) dB lower, or 70 dBc.

M T3 H 0113 H Typical Downconversion Spurious Suppression a Configuration, Sine Wave Lo 6

Upconversion Spurious Suppression


Spurious data is taken by mixing an input within the IF band, with LO frequencies (+mLO+nIF), to create a spurious output within the RF output band. The mixer is swept across the full spurious output band and the mean is calculated. The numbers shown in the table below are for a -10 dBm IF input. Spurious suppression is scaled for different IF input power levels by (n-1), where “n” is the IF spur order. For example, the 2IFx1LO spur is typically 62 dBc for the A configuration for a -10 dBm input, so a -20 dBm IF input creates a spur that is (2-1) x (-10 dB) dB lower, or 72 dBc.

M T3 H 0113 H Typical Upconversion Spurious Suppression a Configuration

Mechanical Data

Outline Drawing

Download : Outline 2D Drawing Outline 3D Drawing Outline 3D STP

Outline Drawing

Revision History

Revision CodeRevision DateComment
-2017-01-01Initial Release
A2019-01-01Revised square wave LO IP3 plots. End note 5 updated to reflect new test condition.

DISCLAIMER

MARKI MICROWAVE, LLC., (“MARKI”) PROVIDES TECHNICAL SPECIFICATIONS AND DATA (INCLUDING DATASHEETS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, AND OTHER INFORMATION AND RESOURCES “AS IS” AND WITH ALL FAULTS. MARKI DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT.

These resources are intended for developers skilled in the art designing with Marki products. You are solely responsible for (1) selecting the appropriate products for your application, (2) designing, validating, and testing your application, and (3) ensuring your application meets applicable standards and other requirements. Marki makes no guarantee regarding the suitability of its products for any particular purpose, nor does Marki assume any liability whatsoever arising out of your use or application of any Marki product.

Marki grants you permission to use these resources only for development of an application that uses Marki products. Other reproduction or use of these resources is strictly prohibited. No license is granted to any other Marki intellectual property or to any third-party intellectual property. Marki reserves the right to make changes to the product(s) or information contained herein without notice.

MARKI MICROWAVE, M wave logo, FastSwitch, and T3 MIXER are trademarks or registered trademarks of Marki Microwave, LLC. All other trademarks used are the property of their respective owners.

© 2017, 2019, Marki Microwave, LLC