Rev: B | Copyright © 2016, 2018 - 2019 Marki Microwave LLC.

General Description

The MM2-0530H is a passive MMIC triple balanced mixer. It features a broadband IF port that spans from 2 to 20 GHz, and has excellent spurious suppression. GaAs MMIC technology improves upon the previous generation of hand assembled, hybrid M2 triple balanced mixers with improved isolations, unit-to-unit repeatability and reliability. The MM2-0530H is available as a wire bondable chip or connectorized SMA package.

Features

  • Broadband IF Port
  • Typical Input 1 dB Compression of +15 dBm
  • High Input IP3 of +21 dBm
  • Excellent LO to IF Isolation
  • Unit-to-Unit Repeatability
  • RoHS Compliant

Functional Block Diagram

Block Diagram

Electrical Performance Summary

ParameterTypUnit
Conversion Loss 8dB
RF Frequency Range 5 to 30GHz
Input IP3 21dBm
LO Input Power 14 to 20-
IF Frequency Range 2 to 20GHz

Summary only – refer to the Electrical Specifications, Absolute Maximum Ratings, and Recommended Operating Range tables for complete details.

Part Ordering Options

Part NumberDescriptionPackageConnectorsGreen StatusProduct LifecycleExport Classification
MM2-0530HSGaAs MMIC Triple Balanced MixerSStandard

REACH

RoHS

ReleasedEAR99

Table Of Contents

Typical Performance

Conversion Loss: 3 GHz IF, Lowside LO (dB) graph for MM2-0530HS
Conversion Loss: 15 GHz IF, Highside LO (dB) graph for MM2-0530HS
Configuration A Conversion Loss vs. LO Power: 3 GHz IF, Lowside LO (db) graph for MM2-0530HS
Configuration B Conversion Loss vs. LO Power: 3 GHz IF, Lowside LO (db) graph for MM2-0530HS
Configuration A Conversion Loss vs. LO Power: 15 GHz IF, Highside LO (db) graph for MM2-0530HS
Configuration B Conversion Loss vs. LO Power: 15 GHz IF, Highside LO (db) graph for MM2-0530HS
Relative IF Response (dB) graph for MM2-0530HS
Relative IF Response (dB) graph for MM2-0530HS
LO to RF Isolation (dB) graph for MM2-0530HS
LO to IF Isolation (dB) graph for MM2-0530HS
RF to IF Isolation (dB) graph for MM2-0530HS
RF Return Loss (dB) graph for MM2-0530HS
IF Return Loss (dB) graph for MM2-0530HS
LO Return Loss (dB) graph for MM2-0530HS
Input IP3: 3GHz IF, +20 dBm LO Power, Sine Wave LSLO (dBm) graph for MM2-0530HS
Output IP3: 3GHz IF, +20 dBm LO Power, Sine Wave LSLO (dBm) graph for MM2-0530HS
Configuration A Input IP3: 3GHz IF, +20 dBm LO Power, Sine Wave LSLO (dBm) graph for MM2-0530HS
Configuration B Input IP3: 3GHz IF, +20 dBm LO Power, Sine Wave LSLO (dBm) graph for MM2-0530HS
Configuration A Output IP3: 3GHz IF, +20 dBm LO Power, Sine Wave LSLO (dBm) graph for MM2-0530HS
Configuration B Output IP3: 3GHz IF, +20 dBm LO Power, Sine Wave LSLO (dBm) graph for MM2-0530HS
Even LO Harmonic to RF Isolation (dB) graph for MM2-0530HS
Even LO Harmonic to IF Isolation (dB) graph for MM2-0530HS
Odd LO Harmonic to RF Isolation (dB) graph for MM2-0530HS
Odd LO Harmonic to IF Isolation (dB) graph for MM2-0530HS
2RF x 2LO Spurious Suppression (dBc) -10 dBm IF Input graph for MM2-0530HS
2IF x 1LO Spurious Suppression (dBc) -10 dBm IF input graph for MM2-0530HS

Specifications

Electrical Specifications

Specifications guaranteed from -55 to +100°C, measured in a 50Ω system. Specifications are shown for Configurations A (B). RF testing is performed on a sample basis to verify conformance to datasheet guaranteed specifications. Consult factory for more information.

ParameterPort ConfigurationTest ConditionsMinimum
Frequency
(GHz)
Maximum
Frequency
(GHz)
MinTypMaxUnit
Conversion Loss 1ALO/RF=5-30 GHz
IF=2-20GHz
LO Drive Level=20
5 30-8-dB
Input IP3 2ALO/RF=5-30 GHz
IF=2-20GHz
LO Drive Level=15-20
5 30-21-dBm
Input P1dB A LO/RF=5-30 GHz
IF=2-20GHz
LO Drive Level= 15-20
5 30-15-dB
LO-RF Isolation A-- --40-dB
Conversion Loss 3BLO/RF=5-30 GHz
IF=2-20GHz
LO Drive Level=20
5 30-9-dB
Input IP3 4BLO/RF=5-30 GHz
IF=2-20GHz
LO Drive Level=14-20
5 30-28-dBm
Input P1dB BLO/RF=5-30 GHz
IF=2-20GHz
LO Drive Level= 14-20
5 30-20-dB
IF Frequency Range --- -2-20GHz
LO Frequency Range --- -5-30GHz
RF Frequency Range --- -5-30GHz

[1] Measured Conversion Loss measured at 3 GHz fixed IF

[2][4] IP3 depends on LO drive conditions, see plots for more details Part Number Options

[3] Measured Conversion Loss measured at 3 GHz fixed IF.

ParameterMinNominalMaxUnit
LO Input Power 14-20-

Absolute Maximum Ratings

ParameterMaximum RatingUnit
Maximum Operating Temperature 100°C
Maximum Storage Temperature 125°C
Minimum Operating Temperature -55°C
Minimum Storage Temperature -65°C
Port 1 DC Current 21mA
Port 2 DC Current 15mA
Port 3 DC Current 24mA
RF Power Handling (RF+LO), 100°C 20dBm
RF Power Handling (RF+LO), 25°C 25dBm

Package Information

ParameterDetailsRating
Dimensions-14.22 x 13.21mm

Port Configuration and Functions

Port Diagram

Diagram of the port configuration for MM2-0530HS

Port Functions

Configuration A

PortFunctionConnector TypeDescriptionDC Equivalent
Circuit
Port 1LO 2.92FPort 1 is DC short and AC matched to 50 Ω from 5 to 30 GHz. Blocking capacitor is optional.Equivalent circuit for the LO
Port 3RF 2.92FPort 3 is DC short and AC matched to 50 Ω from 5 to 30 GHz. Blocking capacitor is optional.Equivalent circuit for the RF
Port 2IF SMAFPort 2 is DC coupled to the diodes. Blocking capacitor is optional.Equivalent circuit for the IF

Configuration B

PortFunctionConnector TypeDescriptionDC Equivalent
Circuit
Port 1RF 2.92FPort 1 is DC short and AC matched to 50 Ω from 5 to 30 GHz. Blocking capacitor is optional.Equivalent circuit for the RF
Port 2IF SMAFPort 2 is DC coupled to the diodes. Blocking capacitor is optional.Equivalent circuit for the IF
Port 3LO 2.92FPort 3 is DC short and AC matched to 50 Ω from 5 to 30 GHz. Blocking capacitor is optional.Equivalent circuit for the LO

Spur Table

Downconversion Spurious Suppression

Spurious data is taken by selecting RF and LO frequencies (+mLO+nRF) within the 5 to 30 GHz RF/LO bands, which create a 3 GHz IF spurious output. The mixer is swept across the full spurious band and the mean is calculated. The numbers shown in the table below are for a -10 dBm RF input. Spurious suppression is scaled for different RF power levels by (n-1), where “n” is the RF spur order. For example, the 2RFx2LO spur is 66 dBc for the A configuration for a -10 dBm input, so a -20 dBm RF input creates a spur that is (2-1) x (-10 dB) dB lower, or 76 dBc.

M M2 0530 H Typical Down

Upconversion Spurious Suppression

Spurious data is taken by mixing a 3 GHz IF with LO frequencies (+mLO+nIF), which creates an RF within the 5 to 30 GHz RF band. The mixer is swept across the full spurious output band and the mean is calculated. The numbers shown in the table below are for a -10 dBm IF input. Spurious suppression is scaled for different IF input power levels by (n-1), where “n” is the IF spur order. For example, the 2IFx1LO spur is typically 63 dBc for the A configuration for a -10 dBm input, so a -20 dBm IF input creates a spur that is (2-1) x (-10 dB) dB lower, or 73 dBc.

M M2 0530 H Typical Up

Mechanical Data

Outline Drawing

Download : Outline 2D Drawing Outline 3D Drawing Outline 3D STP

Outline Drawing

Revision History

Revision CodeRevision DateComment
-2016-01-01Initial Release
A2018-11-01Correction to Port Designation Description
B2019-08-01Added ground pad dimensions on die

DISCLAIMER

MARKI MICROWAVE, LLC., (“MARKI”) PROVIDES TECHNICAL SPECIFICATIONS AND DATA (INCLUDING DATASHEETS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, AND OTHER INFORMATION AND RESOURCES “AS IS” AND WITH ALL FAULTS. MARKI DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT.

These resources are intended for developers skilled in the art designing with Marki products. You are solely responsible for (1) selecting the appropriate products for your application, (2) designing, validating, and testing your application, and (3) ensuring your application meets applicable standards and other requirements. Marki makes no guarantee regarding the suitability of its products for any particular purpose, nor does Marki assume any liability whatsoever arising out of your use or application of any Marki product.

Marki grants you permission to use these resources only for development of an application that uses Marki products. Other reproduction or use of these resources is strictly prohibited. No license is granted to any other Marki intellectual property or to any third-party intellectual property. Marki reserves the right to make changes to the product(s) or information contained herein without notice.

MARKI MICROWAVE, M wave logo, FastSwitch, and T3 MIXER are trademarks or registered trademarks of Marki Microwave, LLC. All other trademarks used are the property of their respective owners.

© 2016, 2018 - 2019, Marki Microwave, LLC