Rev: B | Copyright © 2017 - 2018 Marki Microwave LLC.

General Description

The MM1-1857H is a passive double balanced MMIC mixer. It features excellent conversion loss, superior isolations and spurious performance across a broad bandwidth, in a highly miniaturized form factor. Accurate, nonlinear simulation models are available for Microwave Office® through the Marki Microwave PDK. The MM1-1857H is available as a wire bondable chip or in a connectorized package. The MM1-1857H is a superior alternative to Marki Microwave carrier and packaged M9 mixers.

Features

  • CAD Optimized for Superior Isolation and Spurious Response
  • Broadband Performance
  • Low LO Drive Requirement
  • Excellent Unit-to-Unit Repeatability
  • RoHS Compliant

Functional Block Diagram

Block Diagram

Electrical Performance Summary

ParameterTypUnit
Conversion Loss 12dB
RF Frequency Range 18 to 57GHz
Input IP3 20dBm
LO Input Power 13 to 21-
IF Frequency Range 0 to 21GHz

Summary only – refer to the Electrical Specifications, Absolute Maximum Ratings, and Recommended Operating Range tables for complete details.

Part Ordering Options

Part NumberDescriptionPackageConnectorsGreen StatusProduct LifecycleExport Classification
MM1-1857HSGaAs MMIC Double Balanced MixerSStandard

REACH

RoHS

ReleasedEAR99

Table Of Contents

Typical Performance

Conversion Loss (dB) graph for MM1-1857HS
Relative IF Response (dB) graph for MM1-1857HS
Configuration A Conversion Loss vs. LO Power (dB) graph for MM1-1857HS
Configuration B Conversion Loss vs. LO Power (dB) graph for MM1-1857HS
LO to RF Isolation (dB) graph for MM1-1857HS
LO to IF Isolation (dB) graph for MM1-1857HS
RF to IF Isolation (dB) graph for MM1-1857HS
IF Return Loss (dB) graph for MM1-1857HS
RF Return Loss (dB) graph for MM1-1857HS
LO Return Loss (dB) graph for MM1-1857HS
Input IP3 (dBm) graph for MM1-1857HS
Output IP3 (dBm) graph for MM1-1857HS
Configuration A Input IP3 vs LO Power (dBm) graph for MM1-1857HS
Configuration A Output IP3 vs LO Power (dBm) graph for MM1-1857HS
Configuration B Input IP3 vs LO Power (dBm) graph for MM1-1857HS
Configuration B Output IP3 vs LO Power (dBm) graph for MM1-1857HS
2RF x 2LO Spurious Suppression (dBc) -10 dBm RF Input graph for MM1-1857HS
2IF x 1LO Spurious Suppression (dBc) -10 dBm IF input graph for MM1-1857HS

Specifications

Electrical Specifications

Specifications guaranteed from -55 to +100°C, measured in a 50Ω system. All bare die are 100% DC tested and 100% visually inspected. RF testing is performed on a sample basis to verify conformance to datasheet guaranteed specifications.

ParameterPort ConfigurationTest ConditionsMinimum
Frequency
(GHz)
Maximum
Frequency
(GHz)
MinTypMaxUnit
Conversion Loss ALO/RF=18-57 GHz
IF=0.2-21 GHz
LO drive level=13 dBm
18 57-12-dB
Conversion Loss ALO/RF=18-57 GHz
IF=DC-0.2 GHz
LO drive level=13 dBm
18 57-7.517dB
Input IP3 ALO/RF=18-57 GHz
IF=DC-21 GHz
LO drive level=13-21 dBm
18 57-20-dBm
Input P1dB ALO/RF=18-57 GHz
IF=DC-21 GHz
LO drive level=13-21 dBm
18 57-9-dBm
Conversion Loss BLO/RF=18-57 GHz
IF=0.2-21 GHz
LO drive level=21 dBm
18 57-13-dB
Conversion Loss BLO/RF=18-57 GHz
IF=DC-0.2 GHz
LO drive level=21 dBm
18 57-819dB
Input IP3 B LO/RF=18-57 GHz
IF=DC-21 GHz
LO drive level=13-21 dBm
18 57-19-dBm
Input P1dB BLO/RF=18-57 GHz
IF=DC-21 GHz
LO drive level=13-21 dBm
18 57-9-dBm
IF Frequency Range --- -0-21GHz
LO Frequency Range --- -18-57GHz
LO-RF Isolation --- --45-dB
RF Frequency Range --- -18-57GHz
ParameterMinNominalMaxUnit
LO Input Power 13-21-

Absolute Maximum Ratings

ParameterMaximum RatingUnit
Maximum Operating Temperature 100°C
Maximum Operating Temperature 125°C
Minimum Operating Temperature -55°C
Minimum Storage Temperature -65°C
Port 1 DC Current 30mA
Port 2 DC Current 22.5mA
RF Power Handling (RF+LO), 100°C 23dBm
RF Power Handling (RF+LO), 25°C 28dBm

Package Information

ParameterDetailsRating
Dimensions-14.22 x 13.21mm

Port Configuration and Functions

Port Diagram

Diagram of the port configuration for MM1-1857HS

Port Functions

Configuration A

PortFunctionConnector TypeDescriptionDC Equivalent
Circuit
Port 3RF 1.85FPort 3 is DC open and AC matched to 50 Ohms from 18 to 57 GHz. Blocking capacitor is optional.Equivalent circuit for the RF
Port 2IF SMAFPort 2 is DC coupled to the diodes. Blocking capacitor is optional.Equivalent circuit for the IF
Port 1LO 1.85FPort 1 is DC short to ground and AC matched to 50 Ohms from 18 to 57 GHz. Blocking capacitor is optional.Equivalent circuit for the LO

Configuration B

PortFunctionConnector TypeDescriptionDC Equivalent
Circuit
Port 3LO 1.85FPort 3 is DC open and AC matched to 50 Ohms from 18 to 57 GHz. Blocking capacitor is optional.Equivalent circuit for the LO
Port 2IF SMAFPort 2 is DC coupled to the diodes. Blocking capacitor is optional.Equivalent circuit for the IF
Port 1RF 1.85FPort 1 is DC short to ground and AC matched to 50 Ohms from 18 to 57 GHz. Blocking capacitor is optional.Equivalent circuit for the RF

Spur Table

Downconversion Spurious Suppression

Spurious data is taken by selecting RF and LO frequencies (+mLO+nRF) within the 18 to 57 GHz RF/LO bands, which create a 91 MHz IF spurious output. The mixer is swept across the full spurious band and the mean is calculated. The numbers shown in the table below are for a -10 dBm RF input. Spurious suppression is scaled for different RF power levels by (n-1), where “n” is the RF spur order. For example, the 2RFx2LO spur is 63 dBc for the A configuration for a -10 dBm input, so a -20 dBm RF input creates a spur that is (2-1) x (-10 dB) dB lower, or73 dBc.

M M1 1857 Hs Typical Downconversion Spurious Suppression a Configuration Sine Wave Lo 5

Specifications are subject to change without notice. Contact Marki Microwave for the most recent specifications and data sheets.

Upconversion Spurious Suppression

Spurious data is taken by mixing a 91 MHz IF with LO frequencies (+mLO+nIF), which creates an RF within the 18 to 57 GHz RF band. The mixer is swept across the full spurious output band and the mean is calculated. The numbers shown in the table below are for a -10 dBm IF input. Spurious suppression is scaled for different IF input power levels by (n-1), where “n” is the IF spur order. For example, the 2IFx1LO spur is typically68 dBc for the A configuration for a -10 dBm input, so a -20 dBm IF input creates a spur that is (2-1) x (-10 dB) dB lower, or 78 dBc.

M M1 1857 Hs Typical Upconversion Spurious Suppression a Configuration Sine Wave Lo 5

Specifications are subject to change without notice. Contact Marki Microwave for the most recent specifications and data sheets.

Mechanical Data

Outline Drawing

Download : Outline 2D Drawing Outline 3D Drawing Outline 3D STP

Outline Drawing

Revision History

Revision CodeRevision DateComment
A2017-11-01Die shrunk from 1.48 x 1.18 mm2 to 1.37 x 1.17 mm2. CH package tolerance added.
B2018-10-01Power Handling rating changed from +25dBm to +28dBm

DISCLAIMER

MARKI MICROWAVE, LLC., (“MARKI”) PROVIDES TECHNICAL SPECIFICATIONS AND DATA (INCLUDING DATASHEETS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, AND OTHER INFORMATION AND RESOURCES “AS IS” AND WITH ALL FAULTS. MARKI DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT.

These resources are intended for developers skilled in the art designing with Marki products. You are solely responsible for (1) selecting the appropriate products for your application, (2) designing, validating, and testing your application, and (3) ensuring your application meets applicable standards and other requirements. Marki makes no guarantee regarding the suitability of its products for any particular purpose, nor does Marki assume any liability whatsoever arising out of your use or application of any Marki product.

Marki grants you permission to use these resources only for development of an application that uses Marki products. Other reproduction or use of these resources is strictly prohibited. No license is granted to any other Marki intellectual property or to any third-party intellectual property. Marki reserves the right to make changes to the product(s) or information contained herein without notice.

MARKI MICROWAVE, M wave logo, FastSwitch, and T3 MIXER are trademarks or registered trademarks of Marki Microwave, LLC. All other trademarks used are the property of their respective owners.

© 2017 - 2018, Marki Microwave, LLC