Rev: A | Copyright © 2018 - 2019 Marki Microwave LLC.

General Description

MM1-0212L is a low power GaAs MMIC double balanced mixer that operates at LO powers as a low as +1 dBm. MM1-0212L is a low frequency, low power S band mixer that works well as both an up and down converter to through X band. This mixer offers low conversion loss and high LO to RF isolations at extremely low LO drives. The sister MM1-0212H and MM1-0212S are recommended for high linearity applications. The MM1-0212L is available as both wire bondable die and as connectorized modules.

Features

  • Low +1 dBm minimum LO drive
  • Low cost X band mixer

Functional Block Diagram

Block Diagram

Electrical Performance Summary

ParameterTypUnit
Conversion Loss 9.5dB
RF Frequency Range 2 to 12GHz
Input IP3 12.5dBm
LO Input Power 1 to 15dBm
IF Frequency Range 0 to 3GHz

Summary only – refer to the Electrical Specifications, Absolute Maximum Ratings, and Recommended Operating Range tables for complete details.

Part Ordering Options

Part NumberDescriptionPackageConnectorsGreen StatusProduct LifecycleExport Classification
MM1-0212LSConnectorized ModuleSStandard

REACH

RoHS

ReleasedEAR99

Table Of Contents

Typical Performance Plots

Conversion Loss: 91 MHz IF, LSLO (dB) graph for MM1-0212LS
Conversion Loss: 1.5GHz IF, HSLO (dB) graph for MM1-0212LS
Configuration A Conversion Loss vs. LO Power: 100 MHz IF (dB) graph for MM1-0212LS
Configuration A Conversion Loss vs. LO Power: 1.5 GHz IF (dB) graph for MM1-0212LS
Configuration B Conversion Loss vs. LO Power: 100 MHz IF (dB) graph for MM1-0212LS
Configuration B Conversion Loss vs. LO Power: 1.5 GHz IF (dB) graph for MM1-0212LS
Relative IF Response (dB) graph for MM1-0212LS
Relative IF Response (dB) graph for MM1-0212LS
LO to RF Isolation (dB) graph for MM1-0212LS
LO to IF Isolation (dB) graph for MM1-0212LS
RF to IF Isolation (dB) graph for MM1-0212LS
RF Return Loss (dB) graph for MM1-0212LS
LO Return Loss (dB) graph for MM1-0212LS
IF Return Loss (dB) graph for MM1-0212LS
IF Return Loss (dB) graph for MM1-0212LS

Typical Performance Plots: IP3

Input IP3 (dBm) graph for MM1-0212LS
Output IP3 (dBm) graph for MM1-0212LS
Configuration A Input IP3 vs LO Power (dBm) graph for MM1-0212LS
Configuration A Output IP3 vs LO Power (dBm) graph for MM1-0212LS
Configuration B Input IP3 vs LO Power (dBm) graph for MM1-0212LS
Configuration B Output IP3 vs LO Power (dBm) graph for MM1-0212LS

Typical Performance Plots: LO Harmonic Isolation

Even LO Harmonic to RF Isolation (dB) graph for MM1-0212LS
Even LO Harmonic to IF Isolation (dB) graph for MM1-0212LS
Odd LO Harmonic to RF Isolation (dB) graph for MM1-0212LS
Odd LO Harmonic to IF Isolation (dB) graph for MM1-0212LS
2RF x 2LO Spurious Suppression (dBc) -10 dBm IF Input graph for MM1-0212LS
2IF x 1LO Spurious Suppression (dBc) -10 dBm IF input graph for MM1-0212LS

Specifications

Electrical Specifications

The electrical specifications apply at TA=+25°C in a 50Ω system. Typical data shown is for the connectorized S package mixer used in the forward direction with a +9 dBm sine wave input. Min and Max limits apply only to our connectorized units and are guaranteed at TA=+25°C. All bare die are 100% DC tested and visually inspected.

ParameterPort ConfigurationTest ConditionsMinimum
Frequency
(GHz)
Maximum
Frequency
(GHz)
MinTypMaxUnit
Conversion Loss 1ARF/LO = 2 - 12 GHz
I = 0.2 - 3 GHz
2 12-9.5-dB
Conversion Loss 2ARF/LO = 2 - 12 GHz
I = DC - 0.2 GHz
2 12-811dB
Input IP3 ARF/LO = 2 - 12 GHz
I = DC - 0.2 GHz
2 12-12.5-dBm
Input P1dB A-- --2-dBm
Conversion Loss 3BRF/LO = 2 - 12 GHz
I = 0.2 - 3 GHz
2 12-11-dB
Conversion Loss 4BRF/LO = 2 - 12 GHz
I = DC - 0.2 GHz
2 12-9.512.5dB
Input IP3 BRF/LO = 2 - 12 GHz
I = DC - 0.2 GHz
2 12-14-dBm
Input P1dB B-- --4-dBm
IF Frequency Range --- -0-3GHz
LO Frequency Range --- -2-12GHz
LO-IF Isolation -IF/LO = 2 - 12 GHz
2 12-49-dB
LO-RF Isolation -RF/LO = 2 - 12 GHz
2 12-47-dB
Noise Figure 5-RF/LO = 2 - 12 GHz
I = DC - 0.2 GHz
2 12-8.5-dB
RF Frequency Range --- -2-12GHz
RF-IF Isolation -RF/IF = 2 - 12 GHz
2 12-39-dB

[1][2][3][4] Measured as a down converter to a fixed 91MHz IF.

[5] Mixer Noise Figure typically measures within 0.5 dB of conversion loss for IF frequencies greater than 5 MHz.

The Recommended Operating Conditions indicate the limits, inside which the device should be operated, to guarantee the performance given in Electrical Specifications Operating outside these limits may not necessarily cause damage to the device, but the performance may degrade outside the limits of the electrical specifications. For limits, above which damage may occur, see Absolute Maximum Ratings.

ParameterMinNominalMaxUnit
Ambient Temperature -5525100°C
LO Input Power 1-15dBm

Absolute Maximum Ratings

The Absolute Maximum Ratings indicate limits beyond which damage may occur to the device. If these limits are exceeded, the device may be inoperable or have a reduced lifetime.

ParameterMaximum RatingUnit
Maximum Operating Temperature 100°C
Maximum Storage Temperature 125°C
Minimum Operating Temperature -55°C
Minimum Storage Temperature -65°C
Port 1 DC Current 30mA
Port 2 DC Current 30mA
Power Handling, at any Port 30dBm

Package Information

ParameterDetailsRating
ESD250 to < 500 VoltsHBM Class 1A
WeightPackage name: S10g
Dimensions-14.22 x 13.21 mm

Sequencing Requirements

There is no requirement to apply power to the ports in a specific order. However, it is recommended to provide a 50Ω termination to each port before applying power. This is a passive diode mixer that requires no DC bias.

Port Configuration and Functions

Port Diagram

The MM1-0212L has the input and output ports given in Port Functions. The MM1-0212L can be used in either an up or down conversion. For configuration A, input the LO into port 1, use port 3 for the RF, and port 2 for the IF. For configuration B, input the LO into port 3, use port 1 for the RF, and port 2 for the IF.

Diagram of the port configuration for MM1-0212LS

Port Functions

Configuration A

PortFunctionConnector TypeDescriptionDC Equivalent
Circuit
GNDGround -S package ground provided through metal housing and outer coax conductor.Equivalent circuit for the Ground
Port 3RF SMAFPort 3 is DC open for the CH and S packages.Equivalent circuit for the RF
Port 1LO SMAFPort 1 is DC short for the CH and S packages.Equivalent circuit for the LO
Port 2IF SMAFPort 2 is diode connected for the CH and S package.Equivalent circuit for the IF

Configuration B

PortFunctionConnector TypeDescriptionDC Equivalent
Circuit
Port 3LO SMAFPort 3 is DC open for the CH and S packages.Equivalent circuit for the LO
Port 1RF SMAFPort 1 is DC short for the CH and S packages.Equivalent circuit for the RF
GNDGround -S package ground provided through metal housing and outer coax conductor.Equivalent circuit for the Ground
Port 2IF SMAFPort 2 is diode connected for the CH and S package.Equivalent circuit for the IF

Spur Table

Typical Spurious Performance: Down-Conversion

Typical spurious data is provided by selecting RF and LO frequencies (± m*LO ± n*RF) within the RF/LO bands, to create a spurious output within the IF band. The mixer is swept across the full spurious band and the mean is calculated. The numbers shown in the table below are for a -10 dBm RF input. Spurious suppression is scaled for different RF power levels by (n-1), where “n” is the RF spur order. For example, the 2RF x 2LO spur is 67 dBc for a -10 dBm input, so a -20 dBm RF input creates a spur that is (2-1) x (-10 dB) lower, or 77 dBc. Data is shown for the frequency plan in 3.6 Typical Performance.

Typical Down Conversion Spurious Suppression Config A

Typical Spurious Performance: Up-Conversion

Typical spurious data is taken by mixing an input within the IF band, with LO frequencies (± m*LO ± n*IF), to create a spurious output within the RF output band. The mixer is swept across the full spurious output band and the mean is calculated. The numbers shown in the table below are for a -10 dBm IF input. Spurious suppression is scaled for different IF input power levels by (n-1), where “n” is the IF spur order. For example, the 2IFx1LO spur is typically 75 dBc for a -10 dBm input with a sine-wave LO, so a -20 dBm IF input creates a spur that is (2-1) x (-10 dB) lower, or 85 dBc. Data is shown for the frequency plan in 3.6 Typical Performance.

Typical up Conversion Spurious Suppression Config A

Mechanical Data

Outline Drawing

Download : Outline 2D Drawing Outline 3D Drawing Outline 3D STP

Outline Drawing

Revision History

Revision CodeRevision DateComment
-2018-01-01Datasheet Initial Release
A2019-01-01Added max power/current spec, ESD rating

DISCLAIMER

MARKI MICROWAVE, LLC., (“MARKI”) PROVIDES TECHNICAL SPECIFICATIONS AND DATA (INCLUDING DATASHEETS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, AND OTHER INFORMATION AND RESOURCES “AS IS” AND WITH ALL FAULTS. MARKI DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT.

These resources are intended for developers skilled in the art designing with Marki products. You are solely responsible for (1) selecting the appropriate products for your application, (2) designing, validating, and testing your application, and (3) ensuring your application meets applicable standards and other requirements. Marki makes no guarantee regarding the suitability of its products for any particular purpose, nor does Marki assume any liability whatsoever arising out of your use or application of any Marki product.

Marki grants you permission to use these resources only for development of an application that uses Marki products. Other reproduction or use of these resources is strictly prohibited. No license is granted to any other Marki intellectual property or to any third-party intellectual property. Marki reserves the right to make changes to the product(s) or information contained herein without notice.

MARKI MICROWAVE, M wave logo, FastSwitch, and T3 MIXER are trademarks or registered trademarks of Marki Microwave, LLC. All other trademarks used are the property of their respective owners.

© 2018 - 2019, Marki Microwave, LLC