Rev: - | Copyright © 2022 - 2026 Marki Microwave LLC.

General Description

M9 mixers double balanced mixers are hybrid assemblies that offer ultra-broadband RF, LO and IF bandwidths. M9 mixers have generally been replaced with MM1 mixers with superior performance, repeatability, and availability. M9 mixers are still used in legacy systems and where an MM1 mixer is not available.

Features

  • LO/RF 9.0 to 42.0 GHz
  • IF 1.0 to 22.0 GHz
  • 10 dB Typical Conversion Loss
  • Ultra-Broadband RF, LO, and IF
  • 2.40 mm Connectors

Functional Block Diagram

Block Diagram

Electrical Performance Summary

ParameterTypUnit
Conversion Loss 9dB
RF Frequency Range 9 to 42GHz
Input IP3 19dBm
LO Input Power 9 to 14-
IF Frequency Range 1 to 22GHz

Summary only – refer to the Electrical Specifications, Absolute Maximum Ratings, and Recommended Operating Range tables for complete details.

Part Ordering Options

Part NumberDescriptionPackageConnectorsGreen StatusProduct LifecycleExport ClassificationRecommended Replacement
M9-0942LNVDouble-Balanced MixersNVStandard

Non-RoHS

Not Recommended for New DesignEAR99MM1-1044LS
M9-0942INVDouble-Balanced MixersNVStandardConsult FactoryNot Recommended for New DesignEAR99MM1-1044HS
M9-0942LNV-2Double-Balanced MixersNVStandardConsult FactoryNot Recommended for New DesignEAR99MM1-1044LS

Table Of Contents

Typical Performance Plots

Conversion Loss (dB) graph for M9-0942LNV
Input IP3 (dBm) graph for M9-0942LNV
Relative IF Response (dB) graph for M9-0942LNV
Low-End Relative IF Response (dB) graph for M9-0942LNV
RF VSWR graph for M9-0942LNV
LO VSWR graph for M9-0942LNV
IF VSWR graph for M9-0942LNV
RF to IF Isolation (dB) graph for M9-0942LNV
LO to RF Isolation (dB) graph for M9-0942LNV
LO to IF Isolation (dB) graph for M9-0942LNV
LO Even Harmonic to RF Isolation (dB) graph for M9-0942LNV
LO Even Harmonic to IF Isolation (dB) graph for M9-0942LNV
LO Odd Harmonic to RF Isolation (dB) graph for M9-0942LNV
LO Odd Harmonic to IF Isolation (dB) graph for M9-0942LNV

Specifications

Electrical Specifications

Specifications guaranteed from -55 to +100°C, measured in a 50-Ohm system.

ParameterTest ConditionsMinimum
Frequency
(GHz)
Maximum
Frequency
(GHz)
MinTypMaxUnit
Conversion Loss LO/RF=9-42 GHz
IF=1-22 GHz
9 42-916dB
Input P1dB LO/RF=9-42 GHz
LO drive level, L Diode Option=9-14 dBm
9 42-2-dBm
IF Frequency Range -- -1-22GHz
Input IP3 -- --19-dBm
LO-RF Isolation -- --28-dB
RF Frequency Range -- -9-42GHz
ParameterMinNominalMaxUnit
LO Input Power 9-14-
LO Input Power 9-14-

Absolute Maximum Ratings

ParameterMaximum RatingUnit
IF DC Current 1Amp
LO DC Current 1Amp
Maximum Operating Temperature 100°C
Maximum Storage Temperature 125°C
Minimum Operating Temperature -55°C
Minimum Storage Temperature -65°C
RF DC Current 1Amp
RF Power Handling (RF+LO), 100°C 20dBm
RF Power Handling (RF+LO), 25°C 23dBm

Package Information

ParameterDetailsRating
ESD< 250 VoltsHBM Class 0
WeightPackage name: NV11g
Dimensions-11.94 x 11.94 mm

Port Configuration and Functions

Port Functions

PortFunctionConnector TypeDescriptionDC Equivalent
Circuit
LOLO 2.4FThe LO port is DC coupled to ground and AC matched to 50 Ohms from 9 to 42 GHz. Blocking capacitor is optional.Equivalent circuit for the LO
RFRF 2.4FThe RF port is DC coupled to ground and AC matched to 50 Ohms from 9 to 42 GHz. Blocking capacitor is optional.Equivalent circuit for the RF
IFIF 2.92FThe IF port is DC coupled to ground and AC matched to 50 Ohms from 1 to 22 GHz. Blocking capacitor is optional.Equivalent circuit for the IF

Spur Table

Downconversion Spurious Suppression

Spurious data is taken by selecting RF and LO frequencies (+mLO+nRF) within the 9 to 42 GHz RF/LO bands, which create a 2.0 GHz IF spurious output. The mixer is swept across the spurious band and the mean is calculated. The numbers shown in the table below are for a -10 dBm RF input. Spurious suppression is scaled for different RF power levels by (n-1), where “n” is the RF spur order. For example, the 2RFx2LO spur is 55 dBc for a -10 dBm input (I-Diode), so a -20 dBm RF input creates a spur that is (2-1) x (-10 dB) dB lower, or 65 dBc.

M9 0942 Lnv Typical Downconversion Spurious Suppression

A sample downconversion spurious sweep is shown below. An LO which is 2.0 GHz higher than the RF is used to create a 2.0 GHz reference IF. A second LO is used to create a 2x2 spurious IF, also at 2.0 GHz (1.0 GHz fundamental IF). The difference between these two output levels is the spurious suppression in dBc. The mean value across the 9 to 40 GHz RF input band is the number shown in the table above.

M9 0942 Lnv Typical Downconversion Spurious Sample

Upconversion Spurious Suppression

Spurious data is taken by mixing a 2.0 GHz IF with LO frequencies (+mLO+nIF) which create an RF within the 9 to 42 GHz RF band. The mixer is swept across the spurious output band and the mean is calculated. The numbers shown in the table below are for a -10 dBm IF input. Spurious suppression is scaled for different IF input power levels by (n-1), where “n” is the IF spur order. For example, the 2IFx1LO spur is typically 57 dBc for a -10 dBm input (I-Diode), so a -20 dBm IF input creates a spur that is (2-1) x (-10 dB) dB lower, or 67 dBc.

M9 0942 Lnv Typical Upconversion Spurious Suppression

A sample upconversion spurious sweep is shown below. A 2.0 GHz reference IF input is used to create an RF output that is 2.0 GHz below the LO input (LO-IF=RF). A second LO (2.0 GHz higher) is combined with the same 2.0 GHz IF input (LO-2xIF=RF) to create the same 9 to 38 GHz RF output band. The difference between these two output levels is the spurious suppression in dBc. The mean value across the RF output band is the number shown in the table above.

M9 0942 Lnv Typical Upconversion Spurious Sample

Mechanical Data

Outline Drawing

Download : Outline 3D Drawing Outline 3D STP

Outline Drawing

Notes

DATA SHEET NOTES:
1. Mixer Conversion Loss Plot IF frequency is 4.0 GHz.
2. Mixer Noise Figure typically measures within 0.5 dB of conversion loss.
3. Conversion Loss typically degrades less than 0.5 dB for LO drives 2 dB below the lowest and 3 dB above highest nominal LO drive levels.
4. Conversion Loss typically degrades less than 0.5 dB at +100°C and improves less than 0.5 dB at -55°C.
5. Unless otherwise specified, L-diode data is taken with +11 dBm LO drive, and I-diode data is taken with +16 dBm drive.
6. Specifications are subject to change without notice. Contact Marki Microwave for the most recent specifications and data sheets.
7. Catalog mixer circuits are continually improved. Configuration control requires custom mixer model numbers and specifications.

DISCLAIMER

MARKI MICROWAVE, LLC., (“MARKI”) PROVIDES TECHNICAL SPECIFICATIONS AND DATA (INCLUDING DATASHEETS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, AND OTHER INFORMATION AND RESOURCES “AS IS” AND WITH ALL FAULTS. MARKI DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT.

These resources are intended for developers skilled in the art designing with Marki products. You are solely responsible for (1) selecting the appropriate products for your application, (2) designing, validating, and testing your application, and (3) ensuring your application meets applicable standards and other requirements. Marki makes no guarantee regarding the suitability of its products for any particular purpose, nor does Marki assume any liability whatsoever arising out of your use or application of any Marki product.

Marki grants you permission to use these resources only for development of an application that uses Marki products. Other reproduction or use of these resources is strictly prohibited. No license is granted to any other Marki intellectual property or to any third-party intellectual property. Marki reserves the right to make changes to the product(s) or information contained herein without notice.

MARKI MICROWAVE, M wave logo, FastSwitch, and T3 MIXER are trademarks or registered trademarks of Marki Microwave, LLC. All other trademarks used are the property of their respective owners.

© 2022 - 2026, Marki Microwave, LLC